CLIA Kit for Ribonuclease A (RNase A)
RNASE1; RNASE; Rnase-A; RNase UpI-1; RIB-1; Ribonuclease,RNase A Family,1(Pancreatic)
- Product No.USCA297Bo
 - Organism SpeciesBos taurus; Bovine (Cattle) Same name, Different species.
 - Test MethodDouble-antibody Sandwich
 - Assay Length2h, 40min
 - Detection Range0.14-100ng/mL
 - SensitivityThe minimum detectable dose of this kit is typically less than 0.05ng/mL.
 - Sample Typeserum, plasma, tissue homogenates and other biological fluids
 - Download Instruction Manual
 - UOM 48T96T 96T*5 96T*10 96T*100
 - 
    FOB
    
                        US$ 353 
For more details, please contact local distributors!US$ 504
For more details, please contact local distributors! US$ 2268
For more details, please contact local distributors! US$ 4284
For more details, please contact local distributors! US$ 35280
For more details, please contact local distributors! 
Specificity of the CLIA Kit for Ribonuclease A (RNase A)
                        This assay has high sensitivity and excellent specificity for detection of Ribonuclease A (RNase A).
                        No significant cross-reactivity or interference between Ribonuclease A (RNase A) and analogues was observed.
                    
Recovery of the CLIA Kit for Ribonuclease A (RNase A)
Matrices listed below were spiked with certain level of recombinant Ribonuclease A (RNase A) and the recovery rates were calculated by comparing the measured value to the expected amount of Ribonuclease A (RNase A) in samples.
| Matrix | Recovery range (%) | Average(%) | 
| serum(n=5) | 86-101 | 90 | 
| EDTA plasma(n=5) | 89-103 | 93 | 
| heparin plasma(n=5) | 88-102 | 98 | 
Precision of the CLIA Kit for Ribonuclease A (RNase A)
                    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ribonuclease A (RNase A) were tested 20 times on one plate, respectively. 
                    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ribonuclease A (RNase A) were tested on 3 different plates, 8 replicates in each plate. 
                    CV(%) = SD/meanX100 
                    Intra-Assay: CV<10% 
                    Inter-Assay: CV<12% 
                
Linearity of the CLIA Kit for Ribonuclease A (RNase A)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Ribonuclease A (RNase A) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 | 
| serum(n=5) | 93-103% | 79-94% | 85-103% | 79-97% | 
| EDTA plasma(n=5) | 83-102% | 89-97% | 86-101% | 93-101% | 
| heparin plasma(n=5) | 97-104% | 79-102% | 95-105% | 95-103% | 
Stability of the CLIA Kit for Ribonuclease A (RNase A)
                    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. 
                    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
                
Assay procedure summary of the CLIA Kit for Ribonuclease A (RNase A)
                    1. Prepare all reagents, samples and standards;
                            2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
                            3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
                            4. Aspirate and wash 3 times;
                            5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
                            6. Aspirate and wash 5 times;
                            7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
                            8. Read RLU value immediately.
                
Test principle of the CLIA Kit for Ribonuclease A (RNase A)
The microplate provided in this kit has been pre-coated with an antibody specific to Ribonuclease A (RNase A). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Ribonuclease A (RNase A). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Ribonuclease A (RNase A) level in the sample or standard.;
GIVEAWAYS
INCREMENT SERVICES
                    Single-component Reagents of Assay Kit
                            Lysis Buffer Specific for ELISA / CLIA
                            Quality Control of Kit
                            CLIA Kit Customized Service
                            Disease Model Customized Service
                            Serums Customized Service
                            TGFB1 Activation Reagent
                            Real Time PCR Experimental Service
                            Streptavidin
                            Fast blue Protein Stain solution
                            Single-component Reagents of FLIA Kit
                            Streptavidin-Agarose Beads
                                            
Related products
| Catalog No. | Organism species: Bos taurus; Bovine (Cattle) | Applications (RESEARCH USE ONLY!) | 
| URPA297Bo02 | Recombinant Ribonuclease A (RNase A) | Positive Control; Immunogen; SDS-PAGE; WB. | 
| URPA297Bo01 | Recombinant Ribonuclease A (RNase A) | Positive Control; Immunogen; SDS-PAGE; WB. | 
| UPAA297Bo02 | Polyclonal Antibody to Ribonuclease A (RNase A) | WB; IHC; ICC; IP. | 
| UPAA297Bo01 | Polyclonal Antibody to Ribonuclease A (RNase A) | WB | 
| ULAA297Bo71 | Biotin-Linked Polyclonal Antibody to Ribonuclease A (RNase A) | WB; IHC; ICC. | 
| UMAA297Bo21 | Monoclonal Antibody to Ribonuclease A (RNase A) | WB; IHC; ICC; IP. | 
| USEA297Bo | ELISA Kit for Ribonuclease A (RNase A) | Enzyme-linked immunosorbent assay for Antigen Detection. | 
| USCA297Bo | CLIA Kit for Ribonuclease A (RNase A) | Chemiluminescent immunoassay for Antigen Detection. | 
| ULMA297Bo | Multiplex Assay Kit for Ribonuclease A (RNase A) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. | 