CLIA Kit for Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1)

NTRKR1; Tyrosine-protein kinase transmembrane receptor ROR1; Neurotrophic tyrosine kinase, receptor-related 1

  • CLIA Kit for Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) Packages (Simulation)
  • CLIA Kit for Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) Packages (Simulation)
  • CLIA Kit for Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) Results demonstration
  • SCG522Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1)

This assay has high sensitivity and excellent specificity for detection of Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1).
No significant cross-reactivity or interference between Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) and analogues was observed.

Recovery of the CLIA Kit for Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1)

Matrices listed below were spiked with certain level of recombinant Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) and the recovery rates were calculated by comparing the measured value to the expected amount of Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 97-104 101
EDTA plasma(n=5) 85-95 91
heparin plasma(n=5) 82-96 86

Precision of the CLIA Kit for Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 81-96% 78-90% 87-101% 83-102%
EDTA plasma(n=5) 83-103% 87-94% 81-103% 93-101%
heparin plasma(n=5) 91-98% 80-104% 80-99% 87-96%

Stability of the CLIA Kit for Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1)

The microplate provided in this kit has been pre-coated with an antibody specific to Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPG522Hu01 Recombinant Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) Positive Control; Immunogen; SDS-PAGE; WB.
PAG522Hu01 Polyclonal Antibody to Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) WB; IHC; ICC; IP.
MAG522Hu21 Monoclonal Antibody to Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) WB; IHC; ICC; IP.
SEG522Hu ELISA Kit for Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) Enzyme-linked immunosorbent assay for Antigen Detection.
SCG522Hu CLIA Kit for Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) Chemiluminescent immunoassay for Antigen Detection.
LMG522Hu Multiplex Assay Kit for Receptor Tyrosine Kinase Like Orphan Receptor 1 (ROR1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK