CLIA Kit for Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1)

MOX1; GP91-2; NOH1; NADPH Oxidase 1; Mitogenic Oxidase(Pyridine Nucleotide-Dependent Superoxide-Generating; NADH/NADPH mitogenic oxidase subunit P65-MOX

  • CLIA Kit for Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) Packages (Simulation)
  • CLIA Kit for Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) Packages (Simulation)
  • CLIA Kit for Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) Results demonstration
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1)

This assay has high sensitivity and excellent specificity for detection of Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1).
No significant cross-reactivity or interference between Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) and analogues was observed.

Precision of the CLIA Kit for Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability of the CLIA Kit for Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1)

The microplate provided in this kit has been pre-coated with an antibody specific to Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) level in the sample or standard.;

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
RPA554Ra01 Recombinant Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) Positive Control; Immunogen; SDS-PAGE; WB.
PAA554Ra01 Polyclonal Antibody to Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) WB; IHC; ICC; IP.
MAA554Ra21 Monoclonal Antibody to Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) WB; IHC; ICC; IP.
SEA554Ra ELISA Kit for Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA554Ra CLIA Kit for Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) Chemiluminescent immunoassay for Antigen Detection.
LMA554Ra Multiplex Assay Kit for Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK