- Product No.SCA102Cp
- Organism SpeciesCapra hircus; Caprine (Goat) Same name, Different species.
- Test MethodDouble-antibody Sandwich
- Assay Length2h, 40min
- Detection Range27.4-20,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 11.6pg/mL.
- Sample TypeSerum, plasma and other biological fluids
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 722
For more details, please contact local distributors!US$ 1032
For more details, please contact local distributors! US$ 4644
For more details, please contact local distributors! US$ 8772
For more details, please contact local distributors! US$ 72240
For more details, please contact local distributors!
Specificity of the CLIA Kit for Matrix Metalloproteinase 7 (MMP7)
This assay has high sensitivity and excellent specificity for detection of Matrix Metalloproteinase 7 (MMP7).
No significant cross-reactivity or interference between Matrix Metalloproteinase 7 (MMP7) and analogues was observed.
Recovery of the CLIA Kit for Matrix Metalloproteinase 7 (MMP7)
Matrices listed below were spiked with certain level of recombinant Matrix Metalloproteinase 7 (MMP7) and the recovery rates were calculated by comparing the measured value to the expected amount of Matrix Metalloproteinase 7 (MMP7) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 94-103 | 101 |
heparin plasma(n=5) | 78-98 | 82 |
Precision of the CLIA Kit for Matrix Metalloproteinase 7 (MMP7)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Matrix Metalloproteinase 7 (MMP7) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Matrix Metalloproteinase 7 (MMP7) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the CLIA Kit for Matrix Metalloproteinase 7 (MMP7)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Matrix Metalloproteinase 7 (MMP7) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 87-94% | 96-104% | 78-104% | 80-95% |
heparin plasma(n=5) | 79-101% | 80-101% | 91-101% | 97-105% |
Stability of the CLIA Kit for Matrix Metalloproteinase 7 (MMP7)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the CLIA Kit for Matrix Metalloproteinase 7 (MMP7)
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.
Test principle of the CLIA Kit for Matrix Metalloproteinase 7 (MMP7)
The microplate provided in this kit has been pre-coated with an antibody specific to Matrix Metalloproteinase 7 (MMP7). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Matrix Metalloproteinase 7 (MMP7). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Matrix Metalloproteinase 7 (MMP7) level in the sample or standard.;
GIVEAWAYS
INCREMENT SERVICES
Single-component Reagents of Assay Kit
Lysis Buffer Specific for ELISA / CLIA
Quality Control of Kit
CLIA Kit Customized Service
Disease Model Customized Service
Serums Customized Service
TGFB1 Activation Reagent
Real Time PCR Experimental Service
Streptavidin
Fast blue Protein Stain solution
Single-component Reagents of FLIA Kit
Streptavidin-Agarose Beads
Related products
Catalog No. | Organism species: Capra hircus; Caprine (Goat) | Applications (RESEARCH USE ONLY!) |
RPA102Cp01 | Recombinant Matrix Metalloproteinase 7 (MMP7) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA102Cp01 | Polyclonal Antibody to Matrix Metalloproteinase 7 (MMP7) | WB; IHC; ICC; IP. |
MAA102Cp21 | Monoclonal Antibody to Matrix Metalloproteinase 7 (MMP7) | WB; IHC; ICC; IP. |
SEA102Cp | ELISA Kit for Matrix Metalloproteinase 7 (MMP7) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCA102Cp | CLIA Kit for Matrix Metalloproteinase 7 (MMP7) | Chemiluminescent immunoassay for Antigen Detection. |
LMA102Cp | Multiplex Assay Kit for Matrix Metalloproteinase 7 (MMP7) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |