CLIA Kit for Chemokine (C-X-C Motif) Ligand 2 (CXCL2)

GROb; SCYB2; MIP2; GRO2; MIP2a; MGSAb; CINC2a; HSF; Macrophage inflammatory protein 2-alpha; Hematopoietic synergistic factor; Growth Regulated Oncogene Beta

  • CLIA Kit for Chemokine (C-X-C Motif) Ligand 2 (CXCL2) Packages (Simulation)
  • CLIA Kit for Chemokine (C-X-C Motif) Ligand 2 (CXCL2) Packages (Simulation)
  • CLIA Kit for Chemokine (C-X-C Motif) Ligand 2 (CXCL2) Results demonstration
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Chemokine (C-X-C Motif) Ligand 2 (CXCL2)

This assay has high sensitivity and excellent specificity for detection of Chemokine (C-X-C Motif) Ligand 2 (CXCL2).
No significant cross-reactivity or interference between Chemokine (C-X-C Motif) Ligand 2 (CXCL2) and analogues was observed.

Recovery of the CLIA Kit for Chemokine (C-X-C Motif) Ligand 2 (CXCL2)

Matrices listed below were spiked with certain level of recombinant Chemokine (C-X-C Motif) Ligand 2 (CXCL2) and the recovery rates were calculated by comparing the measured value to the expected amount of Chemokine (C-X-C Motif) Ligand 2 (CXCL2) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 96-103 101
EDTA plasma(n=5) 80-93 87
heparin plasma(n=5) 90-98 94

Precision of the CLIA Kit for Chemokine (C-X-C Motif) Ligand 2 (CXCL2)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chemokine (C-X-C Motif) Ligand 2 (CXCL2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chemokine (C-X-C Motif) Ligand 2 (CXCL2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Chemokine (C-X-C Motif) Ligand 2 (CXCL2)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Chemokine (C-X-C Motif) Ligand 2 (CXCL2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 82-98% 94-103% 81-93% 91-101%
EDTA plasma(n=5) 97-105% 86-99% 94-102% 86-102%
heparin plasma(n=5) 99-105% 82-101% 86-93% 93-101%

Stability of the CLIA Kit for Chemokine (C-X-C Motif) Ligand 2 (CXCL2)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Chemokine (C-X-C Motif) Ligand 2 (CXCL2)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Chemokine (C-X-C Motif) Ligand 2 (CXCL2)

The microplate provided in this kit has been pre-coated with an antibody specific to Chemokine (C-X-C Motif) Ligand 2 (CXCL2). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Chemokine (C-X-C Motif) Ligand 2 (CXCL2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Chemokine (C-X-C Motif) Ligand 2 (CXCL2) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
UAPB603Hu01 Active Chemokine (C-X-C Motif) Ligand 2 (CXCL2) Cell culture; Activity Assays.
URPB603Hu01 Recombinant Chemokine (C-X-C Motif) Ligand 2 (CXCL2) Positive Control; Immunogen; SDS-PAGE; WB.
URPB603Hu02 Recombinant Chemokine (C-X-C Motif) Ligand 2 (CXCL2) Positive Control; Immunogen; SDS-PAGE; WB.
URPB603Hu03 Recombinant Chemokine (C-X-C Motif) Ligand 2 (CXCL2) Positive Control; Immunogen; SDS-PAGE; WB.
UPAB603Hu01 Polyclonal Antibody to Chemokine (C-X-C Motif) Ligand 2 (CXCL2) WB; IHC; ICC; IP.
UPAB603Hu02 Polyclonal Antibody to Chemokine (C-X-C Motif) Ligand 2 (CXCL2) WB,IHC
UPAB603Hu03 Polyclonal Antibody to Chemokine (C-X-C Motif) Ligand 2 (CXCL2) WB; IHC; ICC; IP.
ULAB603Hu71 Biotin-Linked Polyclonal Antibody to Chemokine (C-X-C Motif) Ligand 2 (CXCL2) WB; IHC; ICC.
UMAB603Hu22 Monoclonal Antibody to Chemokine (C-X-C Motif) Ligand 2 (CXCL2) WB; IHC; ICC; IP.
USEB603Hu ELISA Kit for Chemokine (C-X-C Motif) Ligand 2 (CXCL2) Enzyme-linked immunosorbent assay for Antigen Detection.
USCB603Hu CLIA Kit for Chemokine (C-X-C Motif) Ligand 2 (CXCL2) Chemiluminescent immunoassay for Antigen Detection.
ULMB603Hu Multiplex Assay Kit for Chemokine (C-X-C Motif) Ligand 2 (CXCL2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.