CLIA Kit for Glutamine synthetase (GS)
GLNS; GLUL; Glutamate-Ammonia Ligase; Glutamate decarboxylase
- Product No.USCD761Mu
 - Organism SpeciesMus musculus (Mouse) Same name, Different species.
 - Test MethodDouble-antibody Sandwich
 - Assay Length2h, 40min
 - Detection Range0.27-200pg/mL
 - SensitivityThe minimum detectable dose of this kit is typically less than 0.12pg/mL.
 - Sample TypeSerum, plasma, tissue homogenates, cell lysates, cerebrospinal fluid, cell culture supernates and other biological fluids
 - Download Instruction Manual
 - UOM 48T96T 96T*5 96T*10 96T*100
 - 
    FOB
    
                        US$ 302 
For more details, please contact local distributors!US$ 432
For more details, please contact local distributors! US$ 1944
For more details, please contact local distributors! US$ 3672
For more details, please contact local distributors! US$ 30240
For more details, please contact local distributors! 
Specificity of the CLIA Kit for Glutamine synthetase (GS)
                        This assay has high sensitivity and excellent specificity for detection of Glutamine synthetase (GS).
                        No significant cross-reactivity or interference between Glutamine synthetase (GS) and analogues was observed.
                    
Recovery of the CLIA Kit for Glutamine synthetase (GS)
Matrices listed below were spiked with certain level of recombinant Glutamine synthetase (GS) and the recovery rates were calculated by comparing the measured value to the expected amount of Glutamine synthetase (GS) in samples.
| Matrix | Recovery range (%) | Average(%) | 
| serum(n=5) | 89-96 | 93 | 
| EDTA plasma(n=5) | 83-97 | 92 | 
| heparin plasma(n=5) | 85-99 | 93 | 
Precision of the CLIA Kit for Glutamine synthetase (GS)
                    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glutamine synthetase (GS) were tested 20 times on one plate, respectively. 
                    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glutamine synthetase (GS) were tested on 3 different plates, 8 replicates in each plate. 
                    CV(%) = SD/meanX100 
                    Intra-Assay: CV<10% 
                    Inter-Assay: CV<12% 
                
Linearity of the CLIA Kit for Glutamine synthetase (GS)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glutamine synthetase (GS) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 | 
| serum(n=5) | 95-102% | 90-102% | 86-96% | 87-101% | 
| EDTA plasma(n=5) | 88-102% | 78-95% | 88-103% | 97-104% | 
| heparin plasma(n=5) | 92-105% | 82-93% | 99-105% | 82-96% | 
Stability of the CLIA Kit for Glutamine synthetase (GS)
                    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. 
                    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
                
Assay procedure summary of the CLIA Kit for Glutamine synthetase (GS)
                    1. Prepare all reagents, samples and standards;
                            2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
                            3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
                            4. Aspirate and wash 3 times;
                            5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
                            6. Aspirate and wash 5 times;
                            7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
                            8. Read RLU value immediately.
                
Test principle of the CLIA Kit for Glutamine synthetase (GS)
The microplate provided in this kit has been pre-coated with an antibody specific to Glutamine synthetase (GS). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Glutamine synthetase (GS). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Glutamine synthetase (GS) level in the sample or standard.;
GIVEAWAYS
INCREMENT SERVICES
                    Single-component Reagents of Assay Kit
                            Lysis Buffer Specific for ELISA / CLIA
                            Quality Control of Kit
                            CLIA Kit Customized Service
                            Disease Model Customized Service
                            Serums Customized Service
                            TGFB1 Activation Reagent
                            Real Time PCR Experimental Service
                            Streptavidin
                            Fast blue Protein Stain solution
                            Single-component Reagents of FLIA Kit
                            Streptavidin-Agarose Beads
                                            
Related products
| Catalog No. | Organism species: Mus musculus (Mouse) | Applications (RESEARCH USE ONLY!) | 
| URPD761Mu02 | Recombinant Glutamine synthetase (GS) | Positive Control; Immunogen; SDS-PAGE; WB. | 
| URPD761Mu01 | Recombinant Glutamine synthetase (GS) | Positive Control; Immunogen; SDS-PAGE; WB. | 
| UPAD761Mu01 | Polyclonal Antibody to Glutamine synthetase (GS) | WB | 
| UPAD761Mu02 | Polyclonal Antibody to Glutamine synthetase (GS) | WB; IHC; ICC; IP. | 
| ULAD761Mu81 | FITC-Linked Polyclonal Antibody to Glutamine synthetase (GS) | WB; IHC; ICC; IF. | 
| ULAD761Mu71 | Biotin-Linked Polyclonal Antibody to Glutamine synthetase (GS) | WB; IHC; ICC. | 
| USED761Mu | ELISA Kit for Glutamine synthetase (GS) | Enzyme-linked immunosorbent assay for Antigen Detection. | 
| USCD761Mu | CLIA Kit for Glutamine synthetase (GS) | Chemiluminescent immunoassay for Antigen Detection. | 
| ULMD761Mu | Multiplex Assay Kit for Glutamine synthetase (GS) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. | 