CLIA Kit for Ghrelin (GHRL)
MTLRP; Growth Hormone-Releasing Peptide
- Product No.CCA991Ga
- Organism SpeciesChicken (Gallus) Same name, Different species.
- Test MethodCompetitive Inhibition
- Assay Length2h
- Detection Range39.06-10,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 17.31pg/mL.
- Sample TypeSerum, plasma, tissue homogenates, cell culture supernates and other biological fluids
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 638
For more details, please contact local distributors!US$ 912
For more details, please contact local distributors! US$ 4104
For more details, please contact local distributors! US$ 7752
For more details, please contact local distributors! US$ 63840
For more details, please contact local distributors!
Specificity of the CLIA Kit for Ghrelin (GHRL)
This assay has high sensitivity and excellent specificity for detection of Ghrelin (GHRL).
No significant cross-reactivity or interference between Ghrelin (GHRL) and analogues was observed.
Recovery of the CLIA Kit for Ghrelin (GHRL)
Matrices listed below were spiked with certain level of recombinant Ghrelin (GHRL) and the recovery rates were calculated by comparing the measured value to the expected amount of Ghrelin (GHRL) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 96-105 | 101 |
EDTA plasma(n=5) | 79-93 | 89 |
heparin plasma(n=5) | 80-97 | 93 |
Precision of the CLIA Kit for Ghrelin (GHRL)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ghrelin (GHRL) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ghrelin (GHRL) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the CLIA Kit for Ghrelin (GHRL)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Ghrelin (GHRL) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 80-105% | 99-105% | 86-94% | 90-102% |
EDTA plasma(n=5) | 94-103% | 98-105% | 79-96% | 78-98% |
heparin plasma(n=5) | 79-92% | 81-90% | 97-105% | 80-95% |
Stability of the CLIA Kit for Ghrelin (GHRL)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the CLIA Kit for Ghrelin (GHRL)
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.
Test principle of the CLIA Kit for Ghrelin (GHRL)
The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Ghrelin (GHRL). A competitive inhibition reaction is launched between biotin labeled Ghrelin (GHRL) and unlabeled Ghrelin (GHRL) (Standards or samples) with the pre-coated antibody specific to Ghrelin (GHRL). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Ghrelin (GHRL) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Ghrelin (GHRL) level in the sample or standard.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Chicken (Gallus) | Applications (RESEARCH USE ONLY!) |
CEA991Ga | ELISA Kit for Ghrelin (GHRL) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CCA991Ga | CLIA Kit for Ghrelin (GHRL) | Chemiluminescent immunoassay for Antigen Detection. |
LMA991Ga | Multiplex Assay Kit for Ghrelin (GHRL) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |