CLIA Kit for Ethinylestradiol (EE)

Ethinyl Estradiol ; Ethynyl Estradiol; Ethinyl Oestradiol

  • CLIA Kit for Ethinylestradiol (EE) Packages (Simulation)
  • CLIA Kit for Ethinylestradiol (EE) Packages (Simulation)
  • CLIA Kit for Ethinylestradiol (EE) Results demonstration
  • CCK510Ge.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Ethinylestradiol (EE)

This assay has high sensitivity and excellent specificity for detection of Ethinylestradiol (EE).
No significant cross-reactivity or interference between Ethinylestradiol (EE) and analogues was observed.

Recovery of the CLIA Kit for Ethinylestradiol (EE)

Matrices listed below were spiked with certain level of Ethinylestradiol (EE) and the recovery rates were calculated by comparing the measured value to the expected amount of Ethinylestradiol (EE) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 99-105 102
EDTA plasma(n=5) 90-97 94
heparin plasma(n=5) 78-88 83

Precision of the CLIA Kit for Ethinylestradiol (EE)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ethinylestradiol (EE) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ethinylestradiol (EE) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Ethinylestradiol (EE)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Ethinylestradiol (EE) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-103% 93-105% 79-103% 97-104%
EDTA plasma(n=5) 78-89% 96-103% 91-101% 80-94%
heparin plasma(n=5) 83-97% 79-92% 97-104% 89-96%

Stability of the CLIA Kit for Ethinylestradiol (EE)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Ethinylestradiol (EE)

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.

Test principle of the CLIA Kit for Ethinylestradiol (EE)

The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Ethinylestradiol (EE). A competitive inhibition reaction is launched between biotin labeled Ethinylestradiol (EE) and unlabeled Ethinylestradiol (EE) (Standards or samples) with the pre-coated antibody specific to Ethinylestradiol (EE). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Ethinylestradiol (EE) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Ethinylestradiol (EE) level in the sample or standard.

Related products

Catalog No. Organism species: Pan-species (General) Applications (RESEARCH USE ONLY!)
UCPK510Ge11 BSA Conjugated Ethinylestradiol (EE) Immunogen; SDS-PAGE; WB.
UCPK510Ge21 OVA Conjugated Ethinylestradiol (EE) Immunogen; SDS-PAGE; WB.
UPAK510Ge01 Polyclonal Antibody to Ethinylestradiol (EE) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
UMAK510Ge22 Monoclonal Antibody to Ethinylestradiol (EE) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
UMAK510Ge23 Monoclonal Antibody to Ethinylestradiol (EE) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
UMAK510Ge21 Monoclonal Antibody to Ethinylestradiol (EE) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
UCEK510Ge ELISA Kit for Ethinylestradiol (EE) Enzyme-linked immunosorbent assay for Antigen Detection.
UCCK510Ge CLIA Kit for Ethinylestradiol (EE) Chemiluminescent immunoassay for Antigen Detection.
ULMK510Ge Multiplex Assay Kit for Ethinylestradiol (EE) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
UKSK510Ge11 ELISA Kit DIY Materials for Ethinylestradiol (EE) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK