CLIA Kit for Erythroferrone (ERFE)

FAM132B; C1QTNF15; CTRP15; Myonectin; Family With Sequence Similarity 132, Member B; Complement C1q tumor necrosis factor-related protein 15

  • CLIA Kit for Erythroferrone (ERFE) Packages (Simulation)
  • CLIA Kit for Erythroferrone (ERFE) Packages (Simulation)
  • CLIA Kit for Erythroferrone (ERFE) Results demonstration
  • SCU540Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Erythroferrone (ERFE)

This assay has high sensitivity and excellent specificity for detection of Erythroferrone (ERFE).
No significant cross-reactivity or interference between Erythroferrone (ERFE) and analogues was observed.

Recovery of the CLIA Kit for Erythroferrone (ERFE)

Matrices listed below were spiked with certain level of recombinant Erythroferrone (ERFE) and the recovery rates were calculated by comparing the measured value to the expected amount of Erythroferrone (ERFE) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 84-101 89
EDTA plasma(n=5) 95-104 101
heparin plasma(n=5) 89-101 96

Precision of the CLIA Kit for Erythroferrone (ERFE)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Erythroferrone (ERFE) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Erythroferrone (ERFE) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Erythroferrone (ERFE)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Erythroferrone (ERFE) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-94% 86-102% 84-101% 83-103%
EDTA plasma(n=5) 99-105% 88-102% 91-99% 81-97%
heparin plasma(n=5) 94-102% 93-101% 98-105% 79-105%

Stability of the CLIA Kit for Erythroferrone (ERFE)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Erythroferrone (ERFE)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Erythroferrone (ERFE)

The microplate provided in this kit has been pre-coated with an antibody specific to Erythroferrone (ERFE). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Erythroferrone (ERFE). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Erythroferrone (ERFE) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPU540Hu01 Recombinant Erythroferrone (ERFE) Positive Control; Immunogen; SDS-PAGE; WB.
RPU540Hu02 Recombinant Erythroferrone (ERFE) Positive Control; Immunogen; SDS-PAGE; WB.
SEU540Hu ELISA Kit for Erythroferrone (ERFE) Enzyme-linked immunosorbent assay for Antigen Detection.
SCU540Hu CLIA Kit for Erythroferrone (ERFE) Chemiluminescent immunoassay for Antigen Detection.
LMU540Hu Multiplex Assay Kit for Erythroferrone (ERFE) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK