CLIA Kit for Defensin Beta 1 (DEFb1)

B-DF1; DEFB1; BD1; DEF-B1; DEFB101; HBD1

  • CLIA Kit for Defensin Beta 1 (DEFb1) Packages (Simulation)
  • CLIA Kit for Defensin Beta 1 (DEFb1) Packages (Simulation)
  • CLIA Kit for Defensin Beta 1 (DEFb1) Results demonstration
  • SCB373Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Defensin Beta 1 (DEFb1)

This assay has high sensitivity and excellent specificity for detection of Defensin Beta 1 (DEFb1).
No significant cross-reactivity or interference between Defensin Beta 1 (DEFb1) and analogues was observed.

Recovery of the CLIA Kit for Defensin Beta 1 (DEFb1)

Matrices listed below were spiked with certain level of recombinant Defensin Beta 1 (DEFb1) and the recovery rates were calculated by comparing the measured value to the expected amount of Defensin Beta 1 (DEFb1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 94-105 101
EDTA plasma(n=5) 87-95 90
heparin plasma(n=5) 95-104 99

Precision of the CLIA Kit for Defensin Beta 1 (DEFb1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Defensin Beta 1 (DEFb1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Defensin Beta 1 (DEFb1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Defensin Beta 1 (DEFb1)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Defensin Beta 1 (DEFb1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 83-91% 80-88% 81-95% 98-105%
EDTA plasma(n=5) 80-101% 95-104% 96-105% 87-96%
heparin plasma(n=5) 92-99% 82-101% 96-103% 80-91%

Stability of the CLIA Kit for Defensin Beta 1 (DEFb1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Defensin Beta 1 (DEFb1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Defensin Beta 1 (DEFb1)

The microplate provided in this kit has been pre-coated with an antibody specific to Defensin Beta 1 (DEFb1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Defensin Beta 1 (DEFb1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Defensin Beta 1 (DEFb1) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
APB373Hu01 Active Defensin Beta 1 (DEFb1) Cell culture; Activity Assays.
RPB373Hu01 Recombinant Defensin Beta 1 (DEFb1) Positive Control; Immunogen; SDS-PAGE; WB.
PAB373Hu01 Polyclonal Antibody to Defensin Beta 1 (DEFb1) WB; IHC; ICC; IP.
MAB373Hu22 Monoclonal Antibody to Defensin Beta 1 (DEFb1) WB; IHC; ICC; IP.
SEB373Hu ELISA Kit for Defensin Beta 1 (DEFb1) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB373Hu CLIA Kit for Defensin Beta 1 (DEFb1) Chemiluminescent immunoassay for Antigen Detection.
LMB373Hu Multiplex Assay Kit for Defensin Beta 1 (DEFb1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK