CLIA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1)

NTN; ABCD3; C3Xkine; CXC3; CXC3C; NTT; SCYD1; ABCD3; FKN; Neurotactin; Fractalkine; Small Inducible Cytokine Subfamily D(Cys-X3-Cys)Member 1

  • CLIA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Packages (Simulation)
  • CLIA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Packages (Simulation)
  • CLIA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Results demonstration
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1)

This assay has high sensitivity and excellent specificity for detection of Chemokine C-X3-C-Motif Ligand 1 (CX3CL1).
No significant cross-reactivity or interference between Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) and analogues was observed.

Recovery of the CLIA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1)

Matrices listed below were spiked with certain level of recombinant Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) and the recovery rates were calculated by comparing the measured value to the expected amount of Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 86-101 97
EDTA plasma(n=5) 79-93 86
heparin plasma(n=5) 85-105 92

Precision of the CLIA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-97% 91-98% 91-105% 90-98%
EDTA plasma(n=5) 80-89% 79-93% 86-93% 81-93%
heparin plasma(n=5) 94-102% 85-99% 85-95% 93-103%

Stability of the CLIA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1)

The microplate provided in this kit has been pre-coated with an antibody specific to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) level in the sample or standard.;

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPA040Mu02 Recombinant Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Positive Control; Immunogen; SDS-PAGE; WB.
APA040Mu61 Active Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Cell culture; Activity Assays.
EPA040Mu61 Eukaryotic Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Positive Control; Immunogen; SDS-PAGE; WB.
RPA040Mu01 Recombinant Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Positive Control; Immunogen; SDS-PAGE; WB.
PAA040Mu01 Polyclonal Antibody to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) WB; IHC; ICC; IP.
PAA040Mu02 Polyclonal Antibody to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) WB; IHC; ICC; IP.