CLIA Kit for Arachidonate-12-Lipoxygenase (ALOX12)

LOX12; 12-LOX; ALOX-12; 12-LO; 12LPG; LOG12; Lipoxygenase 12; 12S-lipoxygenase; Lipoxin synthase 12-LO; Platelet-type lipoxygenase 12

  • CLIA Kit for Arachidonate-12-Lipoxygenase (ALOX12) Packages (Simulation)
  • CLIA Kit for Arachidonate-12-Lipoxygenase (ALOX12) Packages (Simulation)
  • CLIA Kit for Arachidonate-12-Lipoxygenase (ALOX12) Results demonstration
  • SCB965Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Arachidonate-12-Lipoxygenase (ALOX12)

This assay has high sensitivity and excellent specificity for detection of Arachidonate-12-Lipoxygenase (ALOX12).
No significant cross-reactivity or interference between Arachidonate-12-Lipoxygenase (ALOX12) and analogues was observed.

Precision of the CLIA Kit for Arachidonate-12-Lipoxygenase (ALOX12)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Arachidonate-12-Lipoxygenase (ALOX12) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Arachidonate-12-Lipoxygenase (ALOX12) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability of the CLIA Kit for Arachidonate-12-Lipoxygenase (ALOX12)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Arachidonate-12-Lipoxygenase (ALOX12)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Arachidonate-12-Lipoxygenase (ALOX12)

The microplate provided in this kit has been pre-coated with an antibody specific to Arachidonate-12-Lipoxygenase (ALOX12). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Arachidonate-12-Lipoxygenase (ALOX12). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Arachidonate-12-Lipoxygenase (ALOX12) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
URPB965Hu01 Recombinant Arachidonate-12-Lipoxygenase (ALOX12) Positive Control; Immunogen; SDS-PAGE; WB.
UPAB965Hu01 Polyclonal Antibody to Arachidonate-12-Lipoxygenase (ALOX12) IHC
UMAB965Hu21 Monoclonal Antibody to Arachidonate-12-Lipoxygenase (ALOX12) WB; IHC; ICC; IP.
USEB965Hu ELISA Kit for Arachidonate-12-Lipoxygenase (ALOX12) Enzyme-linked immunosorbent assay for Antigen Detection.
USCB965Hu CLIA Kit for Arachidonate-12-Lipoxygenase (ALOX12) Chemiluminescent immunoassay for Antigen Detection.
ULMB965Hu Multiplex Assay Kit for Arachidonate-12-Lipoxygenase (ALOX12) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK