CLIA Kit for Antithrombin (AT)

AT3; ATIII; SERPINC1; Anti-Thrombin Antibodies; Serpin Peptidase Inhibitor Clade C Member 1; Coding Sequence Signal Peptide Antithrombin Part 1

  • CLIA Kit for Antithrombin (AT) Packages (Simulation)
  • CLIA Kit for Antithrombin (AT) Packages (Simulation)
  • CLIA Kit for Antithrombin (AT) Results demonstration
  • SCC313Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Antithrombin (AT)

This assay has high sensitivity and excellent specificity for detection of Antithrombin (AT).
No significant cross-reactivity or interference between Antithrombin (AT) and analogues was observed.

Recovery of the CLIA Kit for Antithrombin (AT)

Matrices listed below were spiked with certain level of recombinant Antithrombin (AT) and the recovery rates were calculated by comparing the measured value to the expected amount of Antithrombin (AT) in samples.

Matrix Recovery range (%) Average(%)
sodium citrate plasma(n=5) 78-92 81

Precision of the CLIA Kit for Antithrombin (AT)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Antithrombin (AT) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Antithrombin (AT) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Antithrombin (AT)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Antithrombin (AT) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
sodium citrate plasma(n=5) 92-99% 83-90% 85-101% 88-104%

Stability of the CLIA Kit for Antithrombin (AT)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Antithrombin (AT)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Antithrombin (AT)

The microplate provided in this kit has been pre-coated with an antibody specific to Antithrombin (AT). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Antithrombin (AT). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Antithrombin (AT) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
UNPC313Hu01 Native Antithrombin (AT) Positive Control; Immunogen; SDS-PAGE; WB.
UAPC313Hu01 Active Antithrombin (AT) Cell culture; Activity Assays.
URPC313Hu03 Recombinant Antithrombin (AT) Positive Control; Immunogen; SDS-PAGE; WB.
UEPC313Hu61 Eukaryotic Antithrombin (AT) Positive Control; Immunogen; SDS-PAGE; WB.
URPC313Hu01 Recombinant Antithrombin (AT) Positive Control; Immunogen; SDS-PAGE; WB.
URPC313Hu02 Recombinant Antithrombin (AT) Positive Control; Immunogen; SDS-PAGE; WB.
UAPC313Hu61 Active Antithrombin (AT) Cell culture; Activity Assays.
UPAC313Hu01 Polyclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
UPAC313Hu02 Polyclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
UPAC313Hu03 Polyclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
ULAC313Hu81 FITC-Linked Polyclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IF.
ULAC313Hu71 Biotin-Linked Polyclonal Antibody to Antithrombin (AT) WB; IHC; ICC.
UMAC313Hu21 Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
UMAC313Hu27 Monoclonal Antibody to Antithrombin (AT) WB,IHC
UMAC313Hu29 Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
UMAC313Hu23 Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
UMAC313Hu24 Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
UMAC313Hu26 Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
UMAC313Hu22 Monoclonal Antibody to Antithrombin (AT) WB,IHC
UMAC313Hu28 Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
UMAC313Hu25 Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
UFAC313Hu02 Anti-Antithrombin (AT) Monoclonal Antibody FCM
UFAC313Hu04 Anti-Antithrombin (AT) Monoclonal Antibody FCM
UFAC313Hu08 Anti-Antithrombin (AT) Monoclonal Antibody FCM
ULAC313Hu72 Biotin-Linked Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC.
ULAC313Hu82 FITC-Linked Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IF.
USEC313Hu ELISA Kit for Antithrombin (AT) Enzyme-linked immunosorbent assay for Antigen Detection.
USCC313Hu CLIA Kit for Antithrombin (AT) Chemiluminescent immunoassay for Antigen Detection.
ULMC313Hu Multiplex Assay Kit for Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
UKSC313Hu01 ELISA Kit DIY Materials for Antithrombin (AT) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK