CLIA Kit for Anti-Albumin Antibody (Anti-ALB)

Serum albumin

  • CLIA Kit for Anti-Albumin Antibody (Anti-ALB) Packages (Simulation)
  • CLIA Kit for Anti-Albumin Antibody (Anti-ALB) Packages (Simulation)
  • CLIA Kit for Anti-Albumin Antibody (Anti-ALB) Results demonstration
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Anti-Albumin Antibody (Anti-ALB)

This assay has high sensitivity and excellent specificity for detection of Anti-Albumin Antibody (Anti-ALB).
No significant cross-reactivity or interference between Anti-Albumin Antibody (Anti-ALB) and analogues was observed.

Recovery of the CLIA Kit for Anti-Albumin Antibody (Anti-ALB)

Matrices listed below were spiked with certain level of Anti-Albumin Antibody (Anti-ALB) and the recovery rates were calculated by comparing the measured value to the expected amount of Anti-Albumin Antibody (Anti-ALB) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-101 98
EDTA plasma(n=5) 84-98 93
heparin plasma(n=5) 84-92 87

Precision of the CLIA Kit for Anti-Albumin Antibody (Anti-ALB)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Anti-Albumin Antibody (Anti-ALB) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Anti-Albumin Antibody (Anti-ALB) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Anti-Albumin Antibody (Anti-ALB)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Anti-Albumin Antibody (Anti-ALB) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 97-104% 91-99% 93-101% 97-105%
EDTA plasma(n=5) 89-98% 83-97% 86-101% 93-102%
heparin plasma(n=5) 87-101% 99-105% 84-91% 84-98%

Stability of the CLIA Kit for Anti-Albumin Antibody (Anti-ALB)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Anti-Albumin Antibody (Anti-ALB)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Anti-Albumin Antibody (Anti-ALB)

The microplate provided in this kit has been pre-coated with an antibody specific to Anti-Albumin Antibody (Anti-ALB). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Anti-Albumin Antibody (Anti-ALB). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Anti-Albumin Antibody (Anti-ALB) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
UNPB028Hu01 Native Albumin (ALB) Positive Control; Immunogen; SDS-PAGE; WB.
UNPB028Hu02 Native Albumin (ALB) Positive Control; Immunogen; SDS-PAGE; WB.
URPB028Hu01 Recombinant Albumin (ALB) Positive Control; Immunogen; SDS-PAGE; WB.
UEPB028Hu51 Eukaryotic Albumin (ALB) Positive Control; Immunogen; SDS-PAGE; WB.
URPB028Hu51 Recombinant Albumin (ALB) Positive Control; Immunogen; SDS-PAGE; WB.
UPAB028Hu07 Polyclonal Antibody to Albumin (ALB) WB
UPAB028Hu05 Polyclonal Antibody to Albumin (ALB) WB; IHC; ICC; IP.
UPAB028Hu51 Polyclonal Antibody to Albumin (ALB) WB; IHC; ICC; IP.
UPAB028Hu01 Polyclonal Antibody to Albumin (ALB) WB; IHC; ICC; IP.
UPAB028Hu02 Polyclonal Antibody to Albumin (ALB) WB; IHC; ICC; IP.
ULAB028Hu71 Biotin-Linked Polyclonal Antibody to Albumin (ALB) WB; IHC; ICC.
ULAB028Hu81 FITC-Linked Polyclonal Antibody to Albumin (ALB) WB; IHC; ICC; IF.
UMAB028Hu23 Monoclonal Antibody to Albumin (ALB) WB; IHC; ICC; IP.
UMAB028Hu24 Monoclonal Antibody to Albumin (ALB) WB,IHC
UMAB028Hu25 Monoclonal Antibody to Albumin (ALB) WB,IHC
UMAB028Hu26 Monoclonal Antibody to Albumin (ALB) WB,IHC
UMAB028Hu27 Monoclonal Antibody to Albumin (ALB) WB,IHC
UMAB028Hu29 Monoclonal Antibody to Albumin (ALB) WB
UMAB028Hu22 Monoclonal Antibody to Albumin (ALB) WB; IHC
UMAB028Hu28 Monoclonal Antibody to Albumin (ALB) IHC
UMAB028Hu21 Monoclonal Antibody to Albumin (ALB) WB; IHC; ICC; IP.
UHEB028Hu High Sensitive ELISA Kit for Albumin (ALB) Enzyme-linked immunosorbent assay for Antigen Detection.
UCEB028Hu ELISA Kit for Albumin (ALB) Enzyme-linked immunosorbent assay for Antigen Detection.
UAEB028Hu ELISA Kit for Anti-Albumin Antibody (Anti-ALB) Enzyme-linked immunosorbent assay for Antibody Detection.
UACB028Hu CLIA Kit for Anti-Albumin Antibody (Anti-ALB) Chemiluminescent immunoassay for Antibody Detection.
UCCB028Hu CLIA Kit for Albumin (ALB) Chemiluminescent immunoassay for Antigen Detection.
ULMB028Hu Multiplex Assay Kit for Albumin (ALB) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
UKSB028Hu11 ELISA Kit DIY Materials for Albumin (ALB) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK