CLIA Kit for Angiotensin I (AngI)
Ang-I; Angiotensin-1
- Product No.CCA811Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Test MethodCompetitive Inhibition
- Assay Length2h
- Detection Range7.81-2,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 2.92pg/mL.
- Sample TypeSerum, plasma, tissue homogenates, cell culture supernates and other biological fluids
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 588
For more details, please contact local distributors!US$ 840
For more details, please contact local distributors! US$ 3780
For more details, please contact local distributors! US$ 7140
For more details, please contact local distributors! US$ 58800
For more details, please contact local distributors!
Specificity of the CLIA Kit for Angiotensin I (AngI)
This assay has high sensitivity and excellent specificity for detection of Angiotensin I (AngI).
No significant cross-reactivity or interference between Angiotensin I (AngI) and analogues was observed.
Recovery of the CLIA Kit for Angiotensin I (AngI)
Matrices listed below were spiked with certain level of recombinant Angiotensin I (AngI) and the recovery rates were calculated by comparing the measured value to the expected amount of Angiotensin I (AngI) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 83-93 | 89 |
EDTA plasma(n=5) | 95-103 | 99 |
heparin plasma(n=5) | 88-102 | 96 |
Precision of the CLIA Kit for Angiotensin I (AngI)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Angiotensin I (AngI) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Angiotensin I (AngI) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the CLIA Kit for Angiotensin I (AngI)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Angiotensin I (AngI) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 89-101% | 87-94% | 79-92% | 98-105% |
EDTA plasma(n=5) | 80-98% | 94-104% | 95-104% | 79-101% |
heparin plasma(n=5) | 94-101% | 89-104% | 78-95% | 82-99% |
Stability of the CLIA Kit for Angiotensin I (AngI)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the CLIA Kit for Angiotensin I (AngI)
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.
Test principle of the CLIA Kit for Angiotensin I (AngI)
The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Angiotensin I (AngI). A competitive inhibition reaction is launched between biotin labeled Angiotensin I (AngI) and unlabeled Angiotensin I (AngI) (Standards or samples) with the pre-coated antibody specific to Angiotensin I (AngI). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Angiotensin I (AngI) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Angiotensin I (AngI) level in the sample or standard.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Homo sapiens (Human) | Applications (RESEARCH USE ONLY!) |
RPA811Hu01 | Recombinant Angiotensin I (AngI) | Positive Control; Immunogen; SDS-PAGE; WB. |
CPA811Hu21 | OVA Conjugated Angiotensin I (AngI) | Immunogen; SDS-PAGE; WB. |
PAA811Hu01 | Polyclonal Antibody to Angiotensin I (AngI) | WB; IHC; ICC; IP. |
LAA811Hu71 | Biotin-Linked Polyclonal Antibody to Angiotensin I (AngI) | WB; IHC; ICC. |
CEA811Hu | ELISA Kit for Angiotensin I (AngI) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CCA811Hu | CLIA Kit for Angiotensin I (AngI) | Chemiluminescent immunoassay for Antigen Detection. |
LMA811Hu | Multiplex Assay Kit for Angiotensin I (AngI) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSA811Hu11 | ELISA Kit DIY Materials for Angiotensin I (AngI) | Main materials for "Do It (ELISA Kit) Yourself". |