CLIA Kit for Allograft inflammatory factor 1 (AIF1)

IBA1; IRT1; Daintain; Protein G1; Ionized calcium-binding adapter molecule 1; G1

  • CLIA Kit for Allograft inflammatory factor 1 (AIF1) Packages (Simulation)
  • CLIA Kit for Allograft inflammatory factor 1 (AIF1) Packages (Simulation)
  • CLIA Kit for Allograft inflammatory factor 1 (AIF1) Results demonstration
  • SCC288Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Allograft inflammatory factor 1 (AIF1)

This assay has high sensitivity and excellent specificity for detection of Allograft inflammatory factor 1 (AIF1).
No significant cross-reactivity or interference between Allograft inflammatory factor 1 (AIF1) and analogues was observed.

Precision of the CLIA Kit for Allograft inflammatory factor 1 (AIF1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Allograft inflammatory factor 1 (AIF1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Allograft inflammatory factor 1 (AIF1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability of the CLIA Kit for Allograft inflammatory factor 1 (AIF1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Allograft inflammatory factor 1 (AIF1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Allograft inflammatory factor 1 (AIF1)

The microplate provided in this kit has been pre-coated with an antibody specific to Allograft inflammatory factor 1 (AIF1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Allograft inflammatory factor 1 (AIF1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Allograft inflammatory factor 1 (AIF1) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
UAPC288Hu61 Active Allograft inflammatory factor 1 (AIF1) Cell culture; Activity Assays.
URPC288Hu02 Recombinant Allograft inflammatory factor 1 (AIF1) Positive Control; Immunogen; SDS-PAGE; WB.
URPC288Hu01 Recombinant Allograft inflammatory factor 1 (AIF1) Positive Control; Immunogen; SDS-PAGE; WB.
UPAC288Hu02 Polyclonal Antibody to Allograft inflammatory factor 1 (AIF1) WB
UPAC288Hu01 Polyclonal Antibody to Allograft inflammatory factor 1 (AIF1) WB; IHC; FCM
ULAC288Hu71 Biotin-Linked Polyclonal Antibody to Allograft inflammatory factor 1 (AIF1) WB; IHC; ICC.
ULAC288Hu81 FITC-Linked Polyclonal Antibody to Allograft inflammatory factor 1 (AIF1) WB; IHC; ICC; IF.
UMAC288Hu21 Monoclonal Antibody to Allograft inflammatory factor 1 (AIF1) WB; IHC; ICC; IP.
UMAC288Hu23 Monoclonal Antibody to Allograft inflammatory factor 1 (AIF1) WB; IHC; ICC; IP.
UMAC288Hu22 Monoclonal Antibody to Allograft inflammatory factor 1 (AIF1) WB; IHC; ICC; IP.
UMAC288Hu24 Monoclonal Antibody to Allograft inflammatory factor 1 (AIF1) WB
ULAC288Hu72 Biotin-Linked Monoclonal Antibody to Allograft inflammatory factor 1 (AIF1) WB; IHC; ICC.
ULAC288Hu82 FITC-Linked Monoclonal Antibody to Allograft inflammatory factor 1 (AIF1) WB; IHC; ICC; IF.
USEC288Hu ELISA Kit for Allograft inflammatory factor 1 (AIF1) Enzyme-linked immunosorbent assay for Antigen Detection.
USCC288Hu CLIA Kit for Allograft inflammatory factor 1 (AIF1) Chemiluminescent immunoassay for Antigen Detection.
ULMC288Hu Multiplex Assay Kit for Allograft inflammatory factor 1 (AIF1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
UKSC288Hu01 ELISA Kit DIY Materials for Allograft inflammatory factor 1 (AIF1) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK