Biotin-Linked Polyclonal Antibody to Tumor Necrosis Factor Alpha (TNFa)
DIF; TNF-A; TNFSF2; Cachectin; Tumor Necrosis Factor Ligand Superfamily Member 2
- Product No.LAA133Ra71
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- SourceAntibody labeling
- Ig Type IgG
- PurificationAntigen-specific affinity chromatography followed by Protein A affinity chromatography
- LabelBiotin
- Original Antibody n/a
- Buffer FormulationPBS, pH7.4, containing 0.02% NaN3, 50% glycerol.
- TraitsLiquid
- Concentration500µg/mL
- Organism Species Moren/a
- ApplicationsWB; IHC; ICC.
If the antibody is used in flow cytometry, please check FCM antibodies. - Download n/a
- UOM 20µl100µl 200µl 1ml 10ml
-
FOB
US$ 88
For more details, please contact local distributors!US$ 204
For more details, please contact local distributors! US$ 292
For more details, please contact local distributors! US$ 730
For more details, please contact local distributors! US$ 2920
For more details, please contact local distributors!
SPECIFITY of the Biotin-Linked Polyclonal Antibody to Tumor Necrosis Factor Alpha (TNFa)
The antibody is a rabbit polyclonal antibody raised against TNFa. It has been selected for its ability to recognize TNFa in immunohistochemical staining and western blotting.
USAGE of the Biotin-Linked Polyclonal Antibody to Tumor Necrosis Factor Alpha (TNFa)
Western blotting: 0.2-2µg/mL;1:250-2500
Immunohistochemistry: 5-20µg/mL;1:25-100
Immunocytochemistry: 5-20µg/mL;1:25-100
Optimal working dilutions must be determined by end user.
STORAGE of the of the Biotin-Linked Polyclonal Antibody to Tumor Necrosis Factor Alpha (TNFa)
Store at 4°C for frequent use. Stored at -20°C in a manual defrost freezer for two year without detectable loss of activity. Avoid repeated freeze-thaw cycles.
STABILITY of the Biotin-Linked Polyclonal Antibody to Tumor Necrosis Factor Alpha (TNFa)
The thermal stability is described by the loss rate. The loss rate was determined by accelerated thermal degradation test, that is, incubate the protein at 37°C for 48h, and no obvious degradation and precipitation were observed. The loss rate is less than 5% within the expiration date under appropriate storage condition.
GIVEAWAYS
INCREMENT SERVICES
Protein A/G Purification Column
Staining Solution for Cells and Tissue
Positive Control for Antibody
Tissue/Sections Customized Service
Phosphorylated Antibody Customized Service
Western Blot (WB) Experiment Service
Immunohistochemistry (IHC) Experiment Service
Immunocytochemistry (ICC) Experiment Service
Flow Cytometry (FCM) Experiment Service
Immunoprecipitation (IP) Experiment Service
Immunofluorescence (IF) Experiment Service
Buffer
DAB Chromogen Kit
SABC Kit
Real Time PCR Experimental Service