Active Erythropoietin (EPO)
EP; Epoetin; Erythropoetin; Hematopoietin; Hemopoietin
- Product No.APA028Hu01
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Buffer FormulationPBS, pH7.4, containing 0.01% SKL, 5% Trehalose.
- TraitsFreeze-dried powder
- Purity> 90%
- Isoelectric Point7.0
- ApplicationsCell culture; Activity Assays.
- Download Instruction Manual
- UOM 10µg50µg 200µg 1mg 5mg
-
FOB
US$ 274
For more details, please contact local distributors!US$ 684
For more details, please contact local distributors! US$ 1368
For more details, please contact local distributors! US$ 4104
For more details, please contact local distributors! US$ 10260
For more details, please contact local distributors!
ACTIVITY TEST of the Active Erythropoietin (EPO)

Erythropoietin (EPO), also known as hematopoietin or hemopoietin, is a glycoprotein cytokine secreted by the kidney in response to cellular hypoxia; it stimulates red blood cell production (erythropoiesis) in the bone marrow. Erythropoietin is an essential hormone for red blood cell production. EPO can cooperate with various other growth factors involved in the development of erythroid lineage from multipotent progenitors. To test the effect of EPO on cell proliferation, TF-1 cells were seeded into triplicate wells of 96-well plates at a density of 5,000 cells/well with 1% serum standard 1640 including various concentrations of recombinant human EPO. After incubated for 72h, cells were observed by inverted microscope and cell proliferation was measured by Cell Counting Kit-8 (CCK-8). Briefly, 10µL of CCK-8 solution was added to each well of the plate, then the absorbance at 450nm was measured using a microplate reader after incubating the plate for 1-4 hours at 37℃. Proliferation of TF-1 cells after incubation with EPO for 72h observed by inverted microscope was shown in Figure 1. Cell viability was assessed by CCK-8 (Cell Counting Kit-8 ) assay after incubation with recombinant EPO for 72h. The result was shown in Figure 2. It was obvious that EPO significantly increased cell viability of TF-1 cells.
(A) TF-1 cells cultured in 1640, stimulated with 5ng/mL EPO for 72h;
(B) Unstimulated TF-1 cells cultured in1640 for 72h.
Figure. Cell proliferation of TF-1 cells after stimulated with EPO.

Figure. Cell proliferation of TF-1 cells after stimulated with EPO
USAGE of the Active Erythropoietin (EPO)
Reconstitute in 10mM PBS (pH7.4) to a concentration of 0.1-1.0 mg/mL. Do not vortex.
STORAGE of the Active Erythropoietin (EPO)
Avoid repeated freeze/thaw cycles. Store at 2-8°C for one month. Aliquot and store at -80°C for 12 months.
STABILITY of the Active Erythropoietin (EPO)
The thermal stability is described by the loss rate. The loss rate was determined by accelerated thermal degradation test, that is, incubate the protein at 37°C for 48h, and no obvious degradation and precipitation were observed. The loss rate is less than 5% within the expiration date under appropriate storage condition.
INCREMENT SERVICES
BCA Protein Quantification Kit
Molecular Mass Marker for Protein
Monoclonal Antibody Customized Service
Polyclonal Antibody Customized Service
Protein Activity Test Experiment Service
Electrophoretic Mobility Shift Assay (EMSA) Experiment Service
Buffer
Lentivirus Packaging Experiment Service
Adenovirus Packaging Experiment Service
Real Time PCR Experimental Service
Spike RBD Protein (S-RBD)
Protein G
Protein A
Related products
Catalog No. | Organism species: Homo sapiens (Human) | Applications (RESEARCH USE ONLY!) |
APA028Hu61 | Active Erythropoietin (EPO) | Cell culture; Activity Assays. |
EPA028Hu61 | Eukaryotic Erythropoietin (EPO) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA028Hu01 | Recombinant Erythropoietin (EPO) | Positive Control; Immunogen; SDS-PAGE; WB. |
APA028Hu01 | Active Erythropoietin (EPO) | Cell culture; Activity Assays. |
APA028Hu62 | Active Erythropoietin (EPO) | Cell culture; Activity Assays. |
PAA028Hu06 | Polyclonal Antibody to Erythropoietin (EPO) | WB; IHC; ICC; IP. |
PAA028Hu01 | Polyclonal Antibody to Erythropoietin (EPO) | WB; IHC; ICC; IP. |
LAA028Hu71 | Biotin-Linked Polyclonal Antibody to Erythropoietin (EPO) | WB; IHC; ICC. |
MAA028Hu23 | Monoclonal Antibody to Erythropoietin (EPO) | WB; IHC; ICC; IP. |
MAA028Hu26 | Monoclonal Antibody to Erythropoietin (EPO) | WB; IHC; ICC; IP. |
MAA028Hu21 | Monoclonal Antibody to Erythropoietin (EPO) | WB; IHC; ICC; IP. |
MAA028Hu24 | Monoclonal Antibody to Erythropoietin (EPO) | WB; IHC; ICC; IP. |
MAA028Hu25 | Monoclonal Antibody to Erythropoietin (EPO) | WB; IHC; ICC; IP. |
MAA028Hu22 | Monoclonal Antibody to Erythropoietin (EPO) | WB,IHC |
SEA028Hu | ELISA Kit for Erythropoietin (EPO) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCA028Hu | CLIA Kit for Erythropoietin (EPO) | Chemiluminescent immunoassay for Antigen Detection. |
LMA028Hu | Multiplex Assay Kit for Erythropoietin (EPO) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSA028Hu01 | ELISA Kit DIY Materials for Erythropoietin (EPO) | Main materials for "Do It (ELISA Kit) Yourself". |