Wide-range ELISA Kit for Monocyte Chemotactic Protein 1 (MCP1)

CCL2; GDCF2; HC11; HSMCR30; MCAF; MCP1; SCYA2; SMC-CF; Chemokine C-C-Motif Ligand 2; Monocyte Chemotactic And Activating Factor; Monocyte Secretory Protein JE

  • Wide-range ELISA Kit for Monocyte Chemotactic Protein 1 (MCP1) Packages (Simulation)
  • Wide-range ELISA Kit for Monocyte Chemotactic Protein 1 (MCP1) Packages (Simulation)
  • Wide-range ELISA Kit for Monocyte Chemotactic Protein 1 (MCP1) Results demonstration
  • WEA087Mi.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Wide-range ELISA Kit for Monocyte Chemotactic Protein 1 (MCP1)

This assay has high sensitivity for detection of Wide-range Monocyte Chemotactic Protein 1 (MCP1).
100% cross-reactivity of Wide-range Monocyte Chemotactic Protein 1 (MCP1) was observed among Mouse, Rat.

Recovery of the Wide-range ELISA Kit for Monocyte Chemotactic Protein 1 (MCP1)

Matrices listed below were spiked with certain level of recombinant Wide-range Monocyte Chemotactic Protein 1 (MCP1) and the recovery rates were calculated by comparing the measured value to the expected amount of Wide-range Monocyte Chemotactic Protein 1 (MCP1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 84-92 87
EDTA plasma(n=5) 83-91 87
heparin plasma(n=5) 87-96 91

Precision of the Wide-range ELISA Kit for Monocyte Chemotactic Protein 1 (MCP1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Wide-range Monocyte Chemotactic Protein 1 (MCP1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Wide-range Monocyte Chemotactic Protein 1 (MCP1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Wide-range ELISA Kit for Monocyte Chemotactic Protein 1 (MCP1)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Wide-range Monocyte Chemotactic Protein 1 (MCP1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 93-101% 99-105% 80-89% 83-95%
EDTA plasma(n=5) 89-104% 95-102% 87-99% 91-99%
heparin plasma(n=5) 99-105% 85-99% 83-97% 81-103%

Stability of the Wide-range ELISA Kit for Monocyte Chemotactic Protein 1 (MCP1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Wide-range ELISA Kit for Monocyte Chemotactic Protein 1 (MCP1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the Wide-range ELISA Kit for Monocyte Chemotactic Protein 1 (MCP1)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Wide-range Monocyte Chemotactic Protein 1 (MCP1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Wide-range Monocyte Chemotactic Protein 1 (MCP1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Wide-range Monocyte Chemotactic Protein 1 (MCP1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Wide-range Monocyte Chemotactic Protein 1 (MCP1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Mus musculus (Mouse), Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
RPA087Mi02 Recombinant Monocyte Chemotactic Protein 1 (MCP1) Positive Control; Immunogen; SDS-PAGE; WB.
SEA087Mi ELISA Kit for Monocyte Chemotactic Protein 1 (MCP1) Enzyme-linked immunosorbent assay for Antigen Detection.
WEA087Mi Wide-range ELISA Kit for Monocyte Chemotactic Protein 1 (MCP1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA087Mi Multiplex Assay Kit for Monocyte Chemotactic Protein 1 (MCP1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK