Multiplex Assay Kit for Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay)

RNA polymerase I termination factor

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 97-105 102
EDTA plasma(n=5) 98-105 101
heparin plasma(n=5) 95-102 98
sodium citrate plasma(n=5) 92-101 97

Precision of the Multiplex Assay Kit for Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 82-104% 97-105% 80-90% 80-96%
EDTA plasma(n=5) 88-101% 91-102% 93-105% 85-95%
heparin plasma(n=5) 87-96% 85-97% 99-105% 85-104%
sodium citrate plasma(n=5) 92-101% 79-97% 80-101% 98-105%

Stability of the Multiplex Assay Kit for Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPG777Hu01 Recombinant Transcription Termination Factor, RNA polymerase I (TTF1) Positive Control; Immunogen; SDS-PAGE; WB.
RPG777Hu03 Recombinant Transcription Termination Factor, RNA polymerase I (TTF1) Positive Control; Immunogen; SDS-PAGE; WB.
RPG777Hu02 Recombinant Transcription Termination Factor, RNA polymerase I (TTF1) Positive Control; Immunogen; SDS-PAGE; WB.
CPG777Hu21 OVA Conjugated Transcription Termination Factor, RNA polymerase I (TTF1) Immunogen; SDS-PAGE; WB.
PAG777Hu01 Polyclonal Antibody to Transcription Termination Factor, RNA polymerase I (TTF1) WB; IHC; ICC; IP.
PAG777Hu02 Polyclonal Antibody to Transcription Termination Factor, RNA polymerase I (TTF1) WB; IHC; ICC; IP.
MAG777Hu21 Monoclonal Antibody to Transcription Termination Factor, RNA polymerase I (TTF1) WB; IHC; ICC; IP.
SEG777Hu ELISA Kit for Transcription Termination Factor, RNA polymerase I (TTF1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMG777Hu Multiplex Assay Kit for Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK