Multiplex Assay Kit for Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay)

TRF; Thyrotropin-Releasing Factor; Thyroliberin; Protirelin; Pro-tirelin; Prothyroliberin; TSH-releasing factor

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 88-102 93
EDTA plasma(n=5) 92-101 97
heparin plasma(n=5) 85-95 89
sodium citrate plasma(n=5) 89-99 95

Precision of the Multiplex Assay Kit for Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-98% 95-102% 91-101% 93-101%
EDTA plasma(n=5) 96-103% 93-103% 86-94% 78-103%
heparin plasma(n=5) 82-90% 80-99% 95-105% 86-98%
sodium citrate plasma(n=5) 83-94% 79-102% 87-99% 83-101%

Stability of the Multiplex Assay Kit for Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards,Labeled antigen and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest.A competitive inhibition reaction is launched between biotin labeled analytes of interest and unlabeled analytes of interest (Standards or samples) with the pre-coated antibody specific to analytes of interest. Following a wash to remove any unbound substances, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE) is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. The MFI developed is reverse proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPA839Hu01 Recombinant Thyrotropin Releasing Hormone (TRH) Positive Control; Immunogen; SDS-PAGE; WB.
CPA839Hu21 OVA Conjugated Thyrotropin Releasing Hormone (TRH) Immunogen; SDS-PAGE; WB.
CPA839Hu31 KLH Conjugated Thyrotropin Releasing Hormone (TRH) Immunogen; SDS-PAGE; WB.
PAA839Hu08 Polyclonal Antibody to Thyrotropin Releasing Hormone (TRH) WB; IHC; ICC; IP.
PAA839Hu01 Polyclonal Antibody to Thyrotropin Releasing Hormone (TRH) WB; IHC; ICC; IP.
LAA839Hu81 FITC-Linked Polyclonal Antibody to Thyrotropin Releasing Hormone (TRH) WB; IHC; ICC; IF.
LAA839Hu71 Biotin-Linked Polyclonal Antibody to Thyrotropin Releasing Hormone (TRH) WB; IHC; ICC.
MAA839Hu22 Monoclonal Antibody to Thyrotropin Releasing Hormone (TRH) WB; IHC; ICC; IP.
SEA839Hu ELISA Kit for Thyrotropin Releasing Hormone (TRH) Enzyme-linked immunosorbent assay for Antigen Detection.
CEA839Hu ELISA Kit for Thyrotropin Releasing Hormone (TRH) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA839Hu Multiplex Assay Kit for Thyrotropin Releasing Hormone (TRH) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA839Hu11 ELISA Kit DIY Materials for Thyrotropin Releasing Hormone (TRH) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK