Multiplex Assay Kit for S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay)

CGRP; P6; CAAF1; CAGC; ENRAGE; MRP6; Calgranulin C; Calcium-binding protein in amniotic fluid 1; Extracellular newly identified RAGE-binding; Migration inhibitory factor-related 6

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-102 99
EDTA plasma(n=5) 93-105 101
heparin plasma(n=5) 79-101 87
sodium citrate plasma(n=5) 85-97 90

Precision of the Multiplex Assay Kit for S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 82-97% 80-102% 82-91% 91-104%
EDTA plasma(n=5) 99-105% 89-96% 81-96% 88-97%
heparin plasma(n=5) 83-101% 88-102% 84-98% 78-97%
sodium citrate plasma(n=5) 93-101% 91-98% 93-103% 92-105%

Stability of the Multiplex Assay Kit for S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPB080Hu01 Recombinant S100 Calcium Binding Protein A12 (S100A12) Positive Control; Immunogen; SDS-PAGE; WB.
PAB080Hu01 Polyclonal Antibody to S100 Calcium Binding Protein A12 (S100A12) WB; IHC; ICC; IP.
LAB080Hu81 FITC-Linked Polyclonal Antibody to S100 Calcium Binding Protein A12 (S100A12) WB; IHC; ICC; IF.
LAB080Hu71 Biotin-Linked Polyclonal Antibody to S100 Calcium Binding Protein A12 (S100A12) WB; IHC; ICC.
MAB080Hu21 Monoclonal Antibody to S100 Calcium Binding Protein A12 (S100A12) WB
MAB080Hu23 Monoclonal Antibody to S100 Calcium Binding Protein A12 (S100A12) WB; IHC; ICC; IP.
MAB080Hu24 Monoclonal Antibody to S100 Calcium Binding Protein A12 (S100A12) WB.
MAB080Hu29 Monoclonal Antibody to S100 Calcium Binding Protein A12 (S100A12) WB; IHC; ICC; IP.
MAB080Hu27 Monoclonal Antibody to S100 Calcium Binding Protein A12 (S100A12) WB; IHC; ICC; IP.
MAB080Hu25 Monoclonal Antibody to S100 Calcium Binding Protein A12 (S100A12) WB,ICC/IF
MAB080Hu22 Monoclonal Antibody to S100 Calcium Binding Protein A12 (S100A12) WB; IHC; ICC; IP.
SEB080Hu ELISA Kit for S100 Calcium Binding Protein A12 (S100A12) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB080Hu Multiplex Assay Kit for S100 Calcium Binding Protein A12 (S100A12) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSB080Hu01 ELISA Kit DIY Materials for S100 Calcium Binding Protein A12 (S100A12) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK