Multiplex Assay Kit for Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay)

ARIA; GGF; HGL; HRG; HRGA; NDF; SMDF; Acetylcholine receptor-inducing activity; Glial growth factor; Heregulin; Neu differentiation factor; Sensory and motor neuron-derived factor

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 89-96 93
EDTA plasma(n=5) 94-102 99
heparin plasma(n=5) 96-105 99

Precision of the Multiplex Assay Kit for Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 82-104% 92-101% 83-97% 80-103%
EDTA plasma(n=5) 93-101% 86-94% 82-97% 81-96%
heparin plasma(n=5) 88-102% 86-95% 91-101% 79-89%

Stability of the Multiplex Assay Kit for Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
APB866Hu01 Active Neuregulin 1 (NRG1) Cell culture; Activity Assays.
RPB866Hu01 Recombinant Neuregulin 1 (NRG1) Positive Control; Immunogen; SDS-PAGE; WB.
PAB866Hu01 Polyclonal Antibody to Neuregulin 1 (NRG1) WB; IHC; ICC; IP.
LAB866Hu71 Biotin-Linked Polyclonal Antibody to Neuregulin 1 (NRG1) WB; IHC; ICC.
MAB866Hu25 Monoclonal Antibody to Neuregulin 1 (NRG1) WB
MAB866Hu27 Monoclonal Antibody to Neuregulin 1 (NRG1) WB; IHC; ICC; IP.
MAB866Hu22 Monoclonal Antibody to Neuregulin 1 (NRG1) WB
MAB866Hu21 Monoclonal Antibody to Neuregulin 1 (NRG1) WB; IHC; ICC; IP.
MAB866Hu23 Monoclonal Antibody to Neuregulin 1 (NRG1) WB; IHC; ICC; IP.
MAB866Hu24 Monoclonal Antibody to Neuregulin 1 (NRG1) WB; IHC; ICC; IP.
SEB866Hu ELISA Kit for Neuregulin 1 (NRG1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB866Hu Multiplex Assay Kit for Neuregulin 1 (NRG1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSB866Hu01 ELISA Kit DIY Materials for Neuregulin 1 (NRG1) Main materials for "Do It(ELISA Kit) Yourself"
GUESTBOOK