Multiplex Assay Kit for Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay)

GDF8; Growth Differentiation Factor 8

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 101
EDTA plasma(n=5) 98-105 102
heparin plasma(n=5) 85-99 93
sodium citrate plasma(n=5) 89-103 98

Precision of the Multiplex Assay Kit for Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 84-101% 80-98% 87-104% 87-101%
EDTA plasma(n=5) 86-101% 84-94% 86-95% 91-99%
heparin plasma(n=5) 84-91% 94-102% 83-104% 86-101%
sodium citrate plasma(n=5) 81-101% 94-103% 92-101% 91-102%

Stability of the Multiplex Assay Kit for Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards,Labeled antigen and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest.A competitive inhibition reaction is launched between biotin labeled analytes of interest and unlabeled analytes of interest (Standards or samples) with the pre-coated antibody specific to analytes of interest. Following a wash to remove any unbound substances, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE) is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. The MFI developed is reverse proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
RPB653Ra01 Recombinant Myostatin (MSTN) Positive Control; Immunogen; SDS-PAGE; WB.
APB653Ra01 Active Myostatin (MSTN) Cell culture; Activity Assays.
CPB653Ra21 OVA Conjugated Myostatin (MSTN) Immunogen; SDS-PAGE; WB.
PAB653Ra08 Polyclonal Antibody to Myostatin (MSTN) WB; IHC; ICC; IP.
PAB653Ra01 Polyclonal Antibody to Myostatin (MSTN) WB,IHC
LAB653Ra71 Biotin-Linked Polyclonal Antibody to Myostatin (MSTN) WB; IHC; ICC.
MAB653Ra21 Monoclonal Antibody to Myostatin (MSTN) WB; IHC; ICC; IP.
SEB653Ra ELISA Kit for Myostatin (MSTN) Enzyme-linked immunosorbent assay for Antigen Detection.
CEB653Ra ELISA Kit for Myostatin (MSTN) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB653Ra CLIA Kit for Myostatin (MSTN) Chemiluminescent immunoassay for Antigen Detection.
LMB653Ra Multiplex Assay Kit for Myostatin (MSTN) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSB653Ra11 ELISA Kit DIY Materials for Myostatin (MSTN) Main materials for "Do It (ELISA Kit) Yourself".