Multiplex Assay Kit for Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay)

p35; IL12-A; CLMF1; NFSK; NKSF1; Natural Killer Cell Stimulatory Factor 1; Cytotoxic Lymphocyte Maturation Factor 1; NF Cell Stimulatory Factor Chain 1

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-102 88
EDTA plasma(n=5) 92-99 95
heparin plasma(n=5) 83-102 89

Precision of the Multiplex Assay Kit for Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 84-99% 79-101% 90-98% 86-96%
EDTA plasma(n=5) 78-94% 79-101% 88-95% 98-105%
heparin plasma(n=5) 78-104% 96-104% 90-97% 78-99%

Stability of the Multiplex Assay Kit for Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
APA059Hu01 Active Interleukin 12A (IL12A) Cell culture; Activity Assays.
RPA059Hu01 Recombinant Interleukin 12A (IL12A) Positive Control; Immunogen; SDS-PAGE; WB.
PAA059Hu01 Polyclonal Antibody to Interleukin 12A (IL12A) WB; IHC; ICC; IP.
LAA059Hu71 Biotin-Linked Polyclonal Antibody to Interleukin 12A (IL12A) WB; IHC; ICC.
LAA059Hu81 FITC-Linked Polyclonal Antibody to Interleukin 12A (IL12A) WB; IHC; ICC; IF.
MAA059Hu21 Monoclonal Antibody to Interleukin 12A (IL12A) WB; IHC; ICC; IP.
MAA059Hu22 Monoclonal Antibody to Interleukin 12A (IL12A) WB
MAA059Hu23 Monoclonal Antibody to Interleukin 12A (IL12A) WB; IHC; ICC; IP.
MAA059Hu24 Monoclonal Antibody to Interleukin 12A (IL12A) WB
MAA059Hu26 Monoclonal Antibody to Interleukin 12A (IL12A) WB; IHC; ICC; IP.
LAA059Hu76 Biotin-Linked Monoclonal Antibody to Interleukin 12A (IL12A) WB; IHC; ICC.
SEA059Hu ELISA Kit for Interleukin 12A (IL12A) Enzyme-linked immunosorbent assay for Antigen Detection.
HEA059Hu High Sensitive ELISA Kit for Interleukin 12A (IL12A) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA059Hu Multiplex Assay Kit for Interleukin 12A (IL12A) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PSA059Hu01 Antibody Pair for Interleukin 12A (IL12A) ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays.
KSA059Hu01 ELISA Kit DIY Materials for Interleukin 12A (IL12A) Main materials for "Do It (ELISA Kit) Yourself".
IGA059Hu21 Mouse Knockin Human Interleukin 12A (IL12A) Animal Experiments; Positive Control.
GUESTBOOK