Multiplex Assay Kit for Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay)

INH-BA; INHB-A; EDF; FRP; Activin A,Activin AB Alpha Polypeptide; Activin beta-A chain; Erythroid differentiation protein

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 89-103 99
EDTA plasma(n=5) 90-103 96
heparin plasma(n=5) 79-90 82

Precision of the Multiplex Assay Kit for Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 81-92% 95-103% 80-88% 93-102%
EDTA plasma(n=5) 88-101% 91-99% 98-105% 87-99%
heparin plasma(n=5) 87-98% 98-105% 85-104% 82-103%

Stability of the Multiplex Assay Kit for Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards,Labeled antigen and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest.A competitive inhibition reaction is launched between biotin labeled analytes of interest and unlabeled analytes of interest (Standards or samples) with the pre-coated antibody specific to analytes of interest. Following a wash to remove any unbound substances, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE) is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. The MFI developed is reverse proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
EPA838Hu61 Eukaryotic Inhibin Beta A (INHbA) Positive Control; Immunogen; SDS-PAGE; WB.
RPA838Hu01 Recombinant Inhibin Beta A (INHbA) Positive Control; Immunogen; SDS-PAGE; WB.
APA838Hu61 Active Inhibin Beta A (INHbA) Cell culture; Activity Assays.
CPA838Hu21 OVA Conjugated Inhibin Beta A (INHbA) Immunogen; SDS-PAGE; WB.
PAA838Hu06 Polyclonal Antibody to Inhibin Beta A (INHbA) WB; IHC; ICC; IP.
PAA838Hu01 Polyclonal Antibody to Inhibin Beta A (INHbA) WB; IHC; ICC; IP.
MAA838Hu22 Monoclonal Antibody to Inhibin Beta A (INHbA) WB,IHC
MAA838Hu21 Monoclonal Antibody to Inhibin Beta A (INHbA) IHC
MAA838Hu23 Monoclonal Antibody to Inhibin Beta A (INHbA) WB; IHC; ICC; IP.
MAA838Hu28 Monoclonal Antibody to Inhibin Beta A (INHbA) WB; IHC; ICC; IP.
CEA838Hu ELISA Kit for Inhibin Beta A (INHbA) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA838Hu Multiplex Assay Kit for Inhibin Beta A (INHbA) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK