Magnetic Luminex Assay Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc.

FLT3LG; FLT3-LG; Flt3-L; FL; Fms-Related Tyrosine Kinase 3 ligand; SL cytokine

(Note: Up to 8-plex in one testing reaction)

  • Magnetic Luminex Assay Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc. Packages (Simulation)
  • Magnetic Luminex Assay Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc. Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Magnetic Luminex Assay Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc.

This assay has high sensitivity and excellent specificity for detection of FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc..
No significant cross-reactivity or interference between FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc. and analogues was observed.

Recovery of the Magnetic Luminex Assay Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc.

Matrices listed below were spiked with certain level of recombinant FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-89 85
EDTA plasma(n=5) 95-105 101
heparin plasma(n=5) 93-101 97
sodium citrate plasma(n=5) 80-91 88

Precision of the Magnetic Luminex Assay Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc.

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Magnetic Luminex Assay Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc.

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-96% 87-95% 90-98% 92-102%
EDTA plasma(n=5) 81-92% 86-104% 91-98% 80-93%
heparin plasma(n=5) 78-102% 80-98% 94-101% 81-101%
sodium citrate plasma(n=5) 99-105% 78-94% 80-98% 78-92%

Stability of the Magnetic Luminex Assay Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc.

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Magnetic Luminex Assay Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc.

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Magnetic Luminex Assay Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc.

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPA038Mu02 Recombinant FMS Like Tyrosine Kinase 3 Ligand (Flt3L) Positive Control; Immunogen; SDS-PAGE; WB.
RPA038Mu01 Recombinant FMS Like Tyrosine Kinase 3 Ligand (Flt3L) Positive Control; Immunogen; SDS-PAGE; WB.
PAA038Mu02 Polyclonal Antibody to FMS Like Tyrosine Kinase 3 Ligand (Flt3L) WB; IHC; ICC; IP.
PAA038Mu01 Polyclonal Antibody to FMS Like Tyrosine Kinase 3 Ligand (Flt3L) WB; IHC; ICC; IP.
SEA038Mu ELISA Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA038Mu CLIA Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L) Chemiluminescent immunoassay for Antigen Detection.
LMA038Mu Magnetic Luminex Assay Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L) ,etc. Magnetic Luminex Assay for Antigen Detection.
GUESTBOOK