Multiplex Assay Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay)

CXCL5; SCYB5; Chemokine C-X-C-Motif Ligand 5; Small Inducible Cytokine Subfamily B(Cys-X-Cys),Member 5; Neutrophil-activating peptide ENA-78

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 85-101 90
EDTA plasma(n=5) 78-96 84
heparin plasma(n=5) 87-95 91

Precision of the Multiplex Assay Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 92-99% 81-101% 79-102% 92-99%
EDTA plasma(n=5) 82-103% 95-105% 78-93% 94-104%
heparin plasma(n=5) 96-105% 93-104% 93-105% 86-104%

Stability of the Multiplex Assay Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
APA860Mu02 Active Epithelial Neutrophil Activating Peptide 78 (ENA78) Cell culture; Activity Assays.
RPA860Mu02 Recombinant Epithelial Neutrophil Activating Peptide 78 (ENA78) Positive Control; Immunogen; SDS-PAGE; WB.
EPA860Mu61 Eukaryotic Epithelial Neutrophil Activating Peptide 78 (ENA78) Positive Control; Immunogen; SDS-PAGE; WB.
EPA860Mu63 Eukaryotic Epithelial Neutrophil Activating Peptide 78 (ENA78) Positive Control; Immunogen; SDS-PAGE; WB.
APA860Mu61 Active Epithelial Neutrophil Activating Peptide 78 (ENA78) Cell culture; Activity Assays.
RPA860Mu01 Recombinant Epithelial Neutrophil Activating Peptide 78 (ENA78) Positive Control; Immunogen; SDS-PAGE; WB.
PAA860Mu02 Polyclonal Antibody to Epithelial Neutrophil Activating Peptide 78 (ENA78) WB; IHC; ICC; IP.
PAA860Mu01 Polyclonal Antibody to Epithelial Neutrophil Activating Peptide 78 (ENA78) WB; IHC; ICC; IP.
LAA860Mu81 FITC-Linked Polyclonal Antibody to Epithelial Neutrophil Activating Peptide 78 (ENA78) WB; IHC; ICC; IF.
LAA860Mu71 Biotin-Linked Polyclonal Antibody to Epithelial Neutrophil Activating Peptide 78 (ENA78) WB; IHC; ICC.
SEA860Mu ELISA Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) Enzyme-linked immunosorbent assay for Antigen Detection.
AEA860Mu ELISA Kit for Anti-Epithelial Neutrophil Activating Peptide 78 Antibody (Anti-ENA78) Enzyme-linked immunosorbent assay for Antibody Detection.
SCA860Mu CLIA Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) Chemiluminescent immunoassay for Antigen Detection.
LMA860Mu Multiplex Assay Kit for Epithelial Neutrophil Activating Peptide 78 (ENA78) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA860Mu01 ELISA Kit DIY Materials for Epithelial Neutrophil Activating Peptide 78 (ENA78) Main materials for "Do It(ELISA Kit) Yourself"
GUESTBOOK