Multiplex Assay Kit for Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay)

GDH; Lambda-CRY; Gul3DH; L-Gulonate 3-Dehydrogenase; Lambda-Crystallin Homolog

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 102
EDTA plasma(n=5) 86-94 90
heparin plasma(n=5) 89-96 92

Precision of the Multiplex Assay Kit for Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 89-97% 92-105% 86-95% 94-101%
EDTA plasma(n=5) 82-102% 80-90% 81-96% 91-101%
heparin plasma(n=5) 89-96% 91-99% 89-103% 81-94%

Stability of the Multiplex Assay Kit for Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPF354Hu01 Recombinant Crystallin Lambda 1 (CRYl1) Positive Control; Immunogen; SDS-PAGE; WB.
RPF354Hu02 Recombinant Crystallin Lambda 1 (CRYl1) Positive Control; Immunogen; SDS-PAGE; WB.
PAF354Hu01 Polyclonal Antibody to Crystallin Lambda 1 (CRYl1) WB
PAF354Hu02 Polyclonal Antibody to Crystallin Lambda 1 (CRYl1) WB,IHC
LAF354Hu81 FITC-Linked Polyclonal Antibody to Crystallin Lambda 1 (CRYl1) WB; IHC; ICC; IF.
LAF354Hu71 Biotin-Linked Polyclonal Antibody to Crystallin Lambda 1 (CRYl1) WB; IHC; ICC.
MAF354Hu21 Monoclonal Antibody to Crystallin Lambda 1 (CRYl1) WB; IHC; ICC; IP.
MAF354Hu22 Monoclonal Antibody to Crystallin Lambda 1 (CRYl1) WB; IHC; ICC; IP.
SEF354Hu ELISA Kit for Crystallin Lambda 1 (CRYl1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMF354Hu Multiplex Assay Kit for Crystallin Lambda 1 (CRYl1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PGF354Hu01 Primer Pair for Crystallin Lambda 1 (CRYl1) PCR