Multiplex Assay Kit for Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay)

Hydrocortisone

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-93 89
EDTA plasma(n=5) 82-99 95
heparin plasma(n=5) 81-95 92

Precision of the Multiplex Assay Kit for Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-98% 84-94% 90-99% 89-104%
EDTA plasma(n=5) 92-105% 96-105% 84-101% 81-99%
heparin plasma(n=5) 99-105% 91-103% 82-103% 99-105%

Stability of the Multiplex Assay Kit for Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards,Labeled antigen and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest.A competitive inhibition reaction is launched between biotin labeled analytes of interest and unlabeled analytes of interest (Standards or samples) with the pre-coated antibody specific to analytes of interest. Following a wash to remove any unbound substances, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE) is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. The MFI developed is reverse proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

INCREMENT SERVICES

Related products

Catalog No. Organism species: Pan-species (General) Applications (RESEARCH USE ONLY!)
CPA462Ge11 BSA Conjugated Cortisol (Cor) Immunogen; SDS-PAGE; WB.
CPA462Ge21 OVA Conjugated Cortisol (Cor) Immunogen; SDS-PAGE; WB.
PAA462Ge01 Polyclonal Antibody to Cortisol (Cor) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
PAA462Ge02 Polyclonal Antibody to Cortisol (Cor) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
LAA462Ge81 FITC-Linked Polyclonal Antibody to Cortisol (Cor) WB; IHC; ICC; IF.
LAA462Ge71 Biotin-Linked Polyclonal Antibody to Cortisol (Cor) WB; IHC; ICC.
MAA462Ge21 Monoclonal Antibody to Cortisol (Cor) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
MAA462Ge22 Monoclonal Antibody to Cortisol (Cor) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
MEA462Ge Mini Samples ELISA Kit for Cortisol (Cor) Enzyme-linked immunosorbent assay for Antigen Detection.
IEA462Ge Instant ELISA Kit for Cortisol (Cor) Enzyme-linked immunosorbent assay for Antigen Detection.
HEA462Ge High Sensitive ELISA Kit for Cortisol (Cor) Enzyme-linked immunosorbent assay for Antigen Detection.
CEA462Ge ELISA Kit for Cortisol (Cor) Enzyme-linked immunosorbent assay for Antigen Detection.
CCA462Ge CLIA Kit for Cortisol (Cor) Chemiluminescent immunoassay for Antigen Detection.
LMA462Ge Multiplex Assay Kit for Cortisol (Cor) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA462Ge11 ELISA Kit DIY Materials for Cortisol (Cor) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK