Multiplex Assay Kit for Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay)

Corticotropin; Adrenocorticotropin

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 89-98 94
EDTA plasma(n=5) 80-91 87
heparin plasma(n=5) 85-101 92
sodium citrate plasma(n=5) 98-105 102

Precision of the Multiplex Assay Kit for Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-101% 94-101% 92-104% 82-92%
EDTA plasma(n=5) 85-92% 93-101% 99-105% 99-105%
heparin plasma(n=5) 90-104% 78-98% 80-98% 82-98%
sodium citrate plasma(n=5) 87-101% 88-98% 78-91% 80-105%

Stability of the Multiplex Assay Kit for Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards,Labeled antigen and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest.A competitive inhibition reaction is launched between biotin labeled analytes of interest and unlabeled analytes of interest (Standards or samples) with the pre-coated antibody specific to analytes of interest. Following a wash to remove any unbound substances, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE) is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. The MFI developed is reverse proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

INCREMENT SERVICES

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
CPA836Hu11 BSA Conjugated Adrenocorticotropic Hormone (ACTH) Immunogen; SDS-PAGE; WB.
CPA836Hu21 OVA Conjugated Adrenocorticotropic Hormone (ACTH) Immunogen; SDS-PAGE; WB.
PAA836Hu08 Polyclonal Antibody to Adrenocorticotropic Hormone (ACTH) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
PAA836Hu02 Polyclonal Antibody to Adrenocorticotropic Hormone (ACTH) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
LAA836Hu81 FITC-Linked Polyclonal Antibody to Adrenocorticotropic Hormone (ACTH) WB; IHC; ICC; IF.
MAA836Hu21 Monoclonal Antibody to Adrenocorticotropic Hormone (ACTH) WB; IHC; ICC; IP.
MAA836Hu28 Monoclonal Antibody to Adrenocorticotropic Hormone (ACTH) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
CEA836Hu ELISA Kit for Adrenocorticotropic Hormone (ACTH) Enzyme-linked immunosorbent assay for Antigen Detection.
CCA836Hu CLIA Kit for Adrenocorticotropic Hormone (ACTH) Chemiluminescent immunoassay for Antigen Detection.
LMA836Hu Multiplex Assay Kit for Adrenocorticotropic Hormone (ACTH) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA836Hu11 ELISA Kit DIY Materials for Adrenocorticotropic Hormone (ACTH) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK