Magnetic Luminex Assay Kit for 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc.

2,5OAS1; 25-OAS1; OAS1; IFI-4; OIAS; OIASI; E18/E16

(Note: Up to 8-plex in one testing reaction)

  • Magnetic Luminex Assay Kit for 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc. Packages (Simulation)
  • Magnetic Luminex Assay Kit for 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc. Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Magnetic Luminex Assay Kit for 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc.

This assay has high sensitivity and excellent specificity for detection of 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc..
No significant cross-reactivity or interference between 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc. and analogues was observed.

Recovery of the Magnetic Luminex Assay Kit for 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc.

Matrices listed below were spiked with certain level of recombinant 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-99 96
EDTA plasma(n=5) 84-101 92
heparin plasma(n=5) 92-99 96
sodium citrate plasma(n=5) 78-99 89

Precision of the Magnetic Luminex Assay Kit for 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc.

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Magnetic Luminex Assay Kit for 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc.

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 97-105% 89-98% 85-98% 92-99%
EDTA plasma(n=5) 86-99% 81-91% 80-101% 93-101%
heparin plasma(n=5) 93-101% 78-103% 87-95% 92-105%
sodium citrate plasma(n=5) 95-102% 84-98% 96-105% 80-97%

Stability of the Magnetic Luminex Assay Kit for 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc.

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Magnetic Luminex Assay Kit for 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc.

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Magnetic Luminex Assay Kit for 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc.

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPC684Hu01 Recombinant 2',5'-Oligoadenylate Synthetase 1 (OAS1) Positive Control; Immunogen; SDS-PAGE; WB.
PAC684Hu01 Polyclonal Antibody to 2',5'-Oligoadenylate Synthetase 1 (OAS1) WB; IHC; ICC; IP.
LAC684Hu71 Biotin-Linked Polyclonal Antibody to 2',5'-Oligoadenylate Synthetase 1 (OAS1) WB; IHC; ICC.
MAC684Hu21 Monoclonal Antibody to 2',5'-Oligoadenylate Synthetase 1 (OAS1) WB; IHC; ICC; IP.
MAC684Hu23 Monoclonal Antibody to 2',5'-Oligoadenylate Synthetase 1 (OAS1) WB; IHC; ICC; IP.
MAC684Hu24 Monoclonal Antibody to 2',5'-Oligoadenylate Synthetase 1 (OAS1) WB; IHC; ICC; IP.
MAC684Hu22 Monoclonal Antibody to 2',5'-Oligoadenylate Synthetase 1 (OAS1) WB; IHC; ICC; IP.
SEC684Hu ELISA Kit for 2',5'-Oligoadenylate Synthetase 1 (OAS1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC684Hu Magnetic Luminex Assay Kit for 2',5'-Oligoadenylate Synthetase 1 (OAS1) ,etc. Magnetic Luminex Assay for Antigen Detection.