ELISA Kit for Urotensin 2 Receptor (UTS2R)

UT; UTS2-R; GPR14; UTR2; Urotensin-II Receptor; Hypocretin Receptor; G Protein-Coupled Receptor 14

  • ELISA Kit for Urotensin 2 Receptor (UTS2R) Packages (Simulation)
  • ELISA Kit for Urotensin 2 Receptor (UTS2R) Packages (Simulation)
  • ELISA Kit for Urotensin 2 Receptor (UTS2R) Results demonstration
  • SEA335Ra.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Urotensin 2 Receptor (UTS2R)

This assay has high sensitivity and excellent specificity for detection of Urotensin 2 Receptor (UTS2R).
No significant cross-reactivity or interference between Urotensin 2 Receptor (UTS2R) and analogues was observed.

Precision of the ELISA Kit for Urotensin 2 Receptor (UTS2R)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Urotensin 2 Receptor (UTS2R) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Urotensin 2 Receptor (UTS2R) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability of the ELISA Kit for Urotensin 2 Receptor (UTS2R)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Urotensin 2 Receptor (UTS2R)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Urotensin 2 Receptor (UTS2R)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Urotensin 2 Receptor (UTS2R). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Urotensin 2 Receptor (UTS2R). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Urotensin 2 Receptor (UTS2R), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Urotensin 2 Receptor (UTS2R) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
RPA335Ra01 Recombinant Urotensin 2 Receptor (UTS2R) Positive Control; Immunogen; SDS-PAGE; WB.
PAA335Ra01 Polyclonal Antibody to Urotensin 2 Receptor (UTS2R) WB; IHC; ICC; IP.
MAA335Ra21 Monoclonal Antibody to Urotensin 2 Receptor (UTS2R) WB; IHC; ICC; IP.
SEA335Ra ELISA Kit for Urotensin 2 Receptor (UTS2R) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA335Ra Multiplex Assay Kit for Urotensin 2 Receptor (UTS2R) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK