ELISA Kit for Phospholipase A2, Group IIA (PLA2G2A)

PLA2; MOM1; PLA2B; PLA2L; PLA2S; PLAS1; sPLA2(platelets,synovial fluid); Non-pancreatic secretory phospholipase A2; Phosphatidylcholine 2-acylhydrolase 2A

  • ELISA Kit for Phospholipase A2, Group IIA (PLA2G2A) Packages (Simulation)
  • ELISA Kit for Phospholipase A2, Group IIA (PLA2G2A) Packages (Simulation)
  • ELISA Kit for Phospholipase A2, Group IIA (PLA2G2A) Results demonstration
  • SED827Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Phospholipase A2, Group IIA (PLA2G2A)

This assay has high sensitivity and excellent specificity for detection of Phospholipase A2, Group IIA (PLA2G2A).
No significant cross-reactivity or interference between Phospholipase A2, Group IIA (PLA2G2A) and analogues was observed.

Recovery of the ELISA Kit for Phospholipase A2, Group IIA (PLA2G2A)

Matrices listed below were spiked with certain level of recombinant Phospholipase A2, Group IIA (PLA2G2A) and the recovery rates were calculated by comparing the measured value to the expected amount of Phospholipase A2, Group IIA (PLA2G2A) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-103 99
EDTA plasma(n=5) 85-104 95
heparin plasma(n=5) 81-101 86

Precision of the ELISA Kit for Phospholipase A2, Group IIA (PLA2G2A)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Phospholipase A2, Group IIA (PLA2G2A) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Phospholipase A2, Group IIA (PLA2G2A) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Phospholipase A2, Group IIA (PLA2G2A)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Phospholipase A2, Group IIA (PLA2G2A) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-101% 94-102% 87-101% 96-103%
EDTA plasma(n=5) 83-96% 90-98% 78-92% 78-90%
heparin plasma(n=5) 92-101% 78-92% 83-97% 88-95%

Stability of the ELISA Kit for Phospholipase A2, Group IIA (PLA2G2A)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Phospholipase A2, Group IIA (PLA2G2A)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Phospholipase A2, Group IIA (PLA2G2A)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Phospholipase A2, Group IIA (PLA2G2A). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Phospholipase A2, Group IIA (PLA2G2A). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Phospholipase A2, Group IIA (PLA2G2A), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Phospholipase A2, Group IIA (PLA2G2A) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPD827Mu01 Recombinant Phospholipase A2, Group IIA (PLA2G2A) Positive Control; Immunogen; SDS-PAGE; WB.
RPD827Mu02 Recombinant Phospholipase A2, Group IIA (PLA2G2A) Positive Control; Immunogen; SDS-PAGE; WB.
PAD827Mu01 Polyclonal Antibody to Phospholipase A2, Group IIA (PLA2G2A) WB; IHC; ICC; IP.