ELISA Kit for Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1)

EAT; MCL1L; MCL1S; BCL2L3; TM; Myeloid Cell Leukemia Sequence 1, Bcl2 Related; Bcl-2-like protein 3; Bcl-2-related protein EAT/mcl1; mcl1/EAT

  • ELISA Kit for Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1) Packages (Simulation)
  • ELISA Kit for Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1) Packages (Simulation)
  • ELISA Kit for Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1) Results demonstration
  • SEC615Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1)

This assay has high sensitivity and excellent specificity for detection of Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1).
No significant cross-reactivity or interference between Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1) and analogues was observed.

Recovery of the ELISA Kit for Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1)

Matrices listed below were spiked with certain level of recombinant Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1) and the recovery rates were calculated by comparing the measured value to the expected amount of Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 86-95 91
EDTA plasma(n=5) 95-104 98
heparin plasma(n=5) 91-99 95

Precision of the ELISA Kit for Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 89-105% 78-90% 97-105% 95-102%
EDTA plasma(n=5) 92-105% 95-105% 84-104% 82-102%
heparin plasma(n=5) 84-99% 98-105% 90-98% 80-90%

Stability of the ELISA Kit for Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPC615Mu01 Recombinant Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1) Positive Control; Immunogen; SDS-PAGE; WB.
RPC615Mu02 Recombinant Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1) Positive Control; Immunogen; SDS-PAGE; WB.
EPC615Mu61 Eukaryotic Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1) Positive Control; Immunogen; SDS-PAGE; WB.
PAC615Mu01 Polyclonal Antibody to Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1) WB; IHC; ICC; IP.
PAC615Mu02 Polyclonal Antibody to Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1) WB; IHC; ICC; IP.
SEC615Mu ELISA Kit for Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC615Mu Multiplex Assay Kit for Induced Myeloid Leukemia Cell Differentiation Protein Mcl-1 (MCL1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK