ELISA Kit for Leukemia Inhibitory Factor (LIF)

CDF; D-FACTOR; HILDA; MLPLI; Cholinergic Differentiation Factor; Differentiation-Stimulating Factor; Melanoma-Derived LPL Inhibitor; Emfilermin

  • ELISA Kit for Leukemia Inhibitory Factor (LIF) Packages (Simulation)
  • ELISA Kit for Leukemia Inhibitory Factor (LIF) Packages (Simulation)
  • ELISA Kit for Leukemia Inhibitory Factor (LIF) Results demonstration
  • SEA085Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Leukemia Inhibitory Factor (LIF)

This assay has high sensitivity and excellent specificity for detection of Leukemia Inhibitory Factor (LIF).
No significant cross-reactivity or interference between Leukemia Inhibitory Factor (LIF) and analogues was observed.

Recovery of the ELISA Kit for Leukemia Inhibitory Factor (LIF)

Matrices listed below were spiked with certain level of recombinant Leukemia Inhibitory Factor (LIF) and the recovery rates were calculated by comparing the measured value to the expected amount of Leukemia Inhibitory Factor (LIF) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-89 85
EDTA plasma(n=5) 83-104 94
heparin plasma(n=5) 90-102 99

Precision of the ELISA Kit for Leukemia Inhibitory Factor (LIF)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Leukemia Inhibitory Factor (LIF) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Leukemia Inhibitory Factor (LIF) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Leukemia Inhibitory Factor (LIF)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Leukemia Inhibitory Factor (LIF) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 89-103% 89-96% 83-91% 95-105%
EDTA plasma(n=5) 99-105% 80-103% 98-105% 98-105%
heparin plasma(n=5) 81-96% 85-102% 90-102% 78-102%

Stability of the ELISA Kit for Leukemia Inhibitory Factor (LIF)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Leukemia Inhibitory Factor (LIF)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Leukemia Inhibitory Factor (LIF)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Leukemia Inhibitory Factor (LIF). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Leukemia Inhibitory Factor (LIF). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Leukemia Inhibitory Factor (LIF), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Leukemia Inhibitory Factor (LIF) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPA085Hu01 Recombinant Leukemia Inhibitory Factor (LIF) Positive Control; Immunogen; SDS-PAGE; WB.
EPA085Hu61 Eukaryotic Leukemia Inhibitory Factor (LIF) Positive Control; Immunogen; SDS-PAGE; WB.
APA085Hu01 Active Leukemia Inhibitory Factor (LIF) Cell culture; Activity Assays.
PAA085Hu01 Polyclonal Antibody to Leukemia Inhibitory Factor (LIF) WB; IHC
MAA085Hu22 Monoclonal Antibody to Leukemia Inhibitory Factor (LIF) WB; IHC; ICC; IP.
MAA085Hu21 Monoclonal Antibody to Leukemia Inhibitory Factor (LIF) WB; IHC; ICC; IP.
MAA085Hu23 Monoclonal Antibody to Leukemia Inhibitory Factor (LIF) WB; IHC; ICC; IP.
MAA085Hu24 Monoclonal Antibody to Leukemia Inhibitory Factor (LIF) WB; IHC; ICC; IP.
SEA085Hu ELISA Kit for Leukemia Inhibitory Factor (LIF) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA085Hu Multiplex Assay Kit for Leukemia Inhibitory Factor (LIF) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK