ELISA Kit for Glucose-6-phosphate Dehydrogenase (G6PD)

Glucose-6-phosphate 1-dehydrogenase

  • ELISA Kit for Glucose-6-phosphate Dehydrogenase (G6PD) Packages (Simulation)
  • ELISA Kit for Glucose-6-phosphate Dehydrogenase (G6PD) Packages (Simulation)
  • ELISA Kit for Glucose-6-phosphate Dehydrogenase (G6PD) Results demonstration
  • SEA716Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Glucose-6-phosphate Dehydrogenase (G6PD)

This assay has high sensitivity and excellent specificity for detection of Glucose-6-phosphate Dehydrogenase (G6PD).
No significant cross-reactivity or interference between Glucose-6-phosphate Dehydrogenase (G6PD) and analogues was observed.

Recovery of the ELISA Kit for Glucose-6-phosphate Dehydrogenase (G6PD)

Matrices listed below were spiked with certain level of recombinant Glucose-6-phosphate Dehydrogenase (G6PD) and the recovery rates were calculated by comparing the measured value to the expected amount of Glucose-6-phosphate Dehydrogenase (G6PD) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 93-101 96
EDTA plasma(n=5) 92-105 102
heparin plasma(n=5) 95-104 101

Precision of the ELISA Kit for Glucose-6-phosphate Dehydrogenase (G6PD)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glucose-6-phosphate Dehydrogenase (G6PD) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glucose-6-phosphate Dehydrogenase (G6PD) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Glucose-6-phosphate Dehydrogenase (G6PD)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glucose-6-phosphate Dehydrogenase (G6PD) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 95-103% 92-101% 79-101% 89-97%
EDTA plasma(n=5) 95-105% 96-104% 78-96% 82-103%
heparin plasma(n=5) 80-93% 82-98% 91-102% 95-103%

Stability of the ELISA Kit for Glucose-6-phosphate Dehydrogenase (G6PD)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Glucose-6-phosphate Dehydrogenase (G6PD)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Glucose-6-phosphate Dehydrogenase (G6PD)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Glucose-6-phosphate Dehydrogenase (G6PD). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Glucose-6-phosphate Dehydrogenase (G6PD). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Glucose-6-phosphate Dehydrogenase (G6PD), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Glucose-6-phosphate Dehydrogenase (G6PD) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPA716Hu02 Recombinant Glucose-6-phosphate Dehydrogenase (G6PD) Positive Control; Immunogen; SDS-PAGE; WB.
APA716Hu01 Active Glucose-6-phosphate Dehydrogenase (G6PD) Cell culture; Activity Assays.
RPA716Hu01 Recombinant Glucose-6-phosphate Dehydrogenase (G6PD) Positive Control; Immunogen; SDS-PAGE; WB.
PAA716Hu02 Polyclonal Antibody to Glucose-6-phosphate Dehydrogenase (G6PD) WB; IHC; ICC; IP.
PAA716Hu01 Polyclonal Antibody to Glucose-6-phosphate Dehydrogenase (G6PD) WB,IHC
LAA716Hu71 Biotin-Linked Polyclonal Antibody to Glucose-6-phosphate Dehydrogenase (G6PD) WB; IHC; ICC.
MAA716Hu22 Monoclonal Antibody to Glucose-6-phosphate Dehydrogenase (G6PD) WB; IHC; ICC; IP.
SEA716Hu ELISA Kit for Glucose-6-phosphate Dehydrogenase (G6PD) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA716Hu Multiplex Assay Kit for Glucose-6-phosphate Dehydrogenase (G6PD) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA716Hu01 ELISA Kit DIY Materials for Glucose-6-phosphate Dehydrogenase (G6PD) Main materials for "Do It(ELISA Kit) Yourself"
GUESTBOOK