ELISA Kit for Electron Transfer Flavoprotein Beta Polypeptide (ETFb)

ETF-B; MADD; FP585

  • ELISA Kit for Electron Transfer Flavoprotein Beta Polypeptide (ETFb) Packages (Simulation)
  • ELISA Kit for Electron Transfer Flavoprotein Beta Polypeptide (ETFb) Packages (Simulation)
  • ELISA Kit for Electron Transfer Flavoprotein Beta Polypeptide (ETFb) Results demonstration
  • SEB642Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Electron Transfer Flavoprotein Beta Polypeptide (ETFb)

This assay has high sensitivity and excellent specificity for detection of Electron Transfer Flavoprotein Beta Polypeptide (ETFb).
No significant cross-reactivity or interference between Electron Transfer Flavoprotein Beta Polypeptide (ETFb) and analogues was observed.

Recovery of the ELISA Kit for Electron Transfer Flavoprotein Beta Polypeptide (ETFb)

Matrices listed below were spiked with certain level of recombinant Electron Transfer Flavoprotein Beta Polypeptide (ETFb) and the recovery rates were calculated by comparing the measured value to the expected amount of Electron Transfer Flavoprotein Beta Polypeptide (ETFb) in samples.

Matrix Recovery range (%) Average(%)
91-98 95

Precision of the ELISA Kit for Electron Transfer Flavoprotein Beta Polypeptide (ETFb)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Electron Transfer Flavoprotein Beta Polypeptide (ETFb) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Electron Transfer Flavoprotein Beta Polypeptide (ETFb) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Electron Transfer Flavoprotein Beta Polypeptide (ETFb)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Electron Transfer Flavoprotein Beta Polypeptide (ETFb) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
82-99% 92-101% 96-105% 96-104%

Stability of the ELISA Kit for Electron Transfer Flavoprotein Beta Polypeptide (ETFb)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Electron Transfer Flavoprotein Beta Polypeptide (ETFb)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Electron Transfer Flavoprotein Beta Polypeptide (ETFb)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Electron Transfer Flavoprotein Beta Polypeptide (ETFb). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Electron Transfer Flavoprotein Beta Polypeptide (ETFb). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Electron Transfer Flavoprotein Beta Polypeptide (ETFb), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Electron Transfer Flavoprotein Beta Polypeptide (ETFb) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPB642Hu01 Recombinant Electron Transfer Flavoprotein Beta Polypeptide (ETFb) Positive Control; Immunogen; SDS-PAGE; WB.
PAB642Hu01 Polyclonal Antibody to Electron Transfer Flavoprotein Beta Polypeptide (ETFb) WB; IHC; ICC; IP.
MAB642Hu21 Monoclonal Antibody to Electron Transfer Flavoprotein Beta Polypeptide (ETFb) WB; IHC; ICC; IP.
SEB642Hu ELISA Kit for Electron Transfer Flavoprotein Beta Polypeptide (ETFb) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB642Hu Multiplex Assay Kit for Electron Transfer Flavoprotein Beta Polypeptide (ETFb) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CGB642Hu01 cDNA of Electron Transfer Flavoprotein Beta Polypeptide (ETFb) PCR; Protein Expression; etc.
GUESTBOOK