ELISA Kit for Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase)

C4b2a; C3bBb, complement C.hivin.4.hivin2

  • ELISA Kit for Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase) Packages (Simulation)
  • ELISA Kit for Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase) Packages (Simulation)
  • ELISA Kit for Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase) Results demonstration
  • AEA758Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase)

This assay has high sensitivity and excellent specificity for detection of Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase).
No significant cross-reactivity or interference between Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase) and analogues was observed.

Recovery of the ELISA Kit for Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase)

Matrices listed below were spiked with certain level of Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase) and the recovery rates were calculated by comparing the measured value to the expected amount of Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 85-102 91
EDTA plasma(n=5) 78-94 84
heparin plasma(n=5) 80-95 80

Precision of the ELISA Kit for Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 89-97% 98-105% 78-104% 80-92%
EDTA plasma(n=5) 78-97% 90-101% 79-97% 88-95%
heparin plasma(n=5) 83-102% 78-101% 98-105% 95-105%

Stability of the ELISA Kit for Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 5 times;
5. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
6. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase)

The microtiter plate provided in this kit has been pre-coated with an antigen. Standards or samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)-conjugated secondary antibody. After TMB substrate solution is added, those wells that contain Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase) will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPA758Hu01 Recombinant Complement C3 Convertase (C3 Convertase) Positive Control; Immunogen; SDS-PAGE; WB.
PAA758Hu01 Polyclonal Antibody to Complement C3 Convertase (C3 Convertase) WB; IHC; ICC; IP.
LAA758Hu81 FITC-Linked Polyclonal Antibody to Complement C3 Convertase (C3 Convertase) WB; IHC; ICC; IF.
LAA758Hu71 Biotin-Linked Polyclonal Antibody to Complement C3 Convertase (C3 Convertase) WB; IHC; ICC.
MAA758Hu21 Monoclonal Antibody to Complement C3 Convertase (C3 Convertase) WB; IHC; ICC; IP.
SEA758Hu ELISA Kit for Complement C3 Convertase (C3 Convertase) Enzyme-linked immunosorbent assay for Antigen Detection.
HEA758Hu High Sensitive ELISA Kit for Complement C3 Convertase (C3 Convertase) Enzyme-linked immunosorbent assay for Antigen Detection.
AEA758Hu ELISA Kit for Anti-Complement C3 Convertase Antibody (Anti-C3 Convertase) Enzyme-linked immunosorbent assay for Antibody Detection.
HCA758Hu High Sensitive CLIA Kit for Complement C3 Convertase (C3 Convertase) Chemiluminescent immunoassay for Antigen Detection.
SCA758Hu CLIA Kit for Complement C3 Convertase (C3 Convertase) Chemiluminescent immunoassay for Antigen Detection.
LMA758Hu Multiplex Assay Kit for Complement C3 Convertase (C3 Convertase) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA758Hu01 ELISA Kit DIY Materials for Complement C3 Convertase (C3 Convertase) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK