CLIA Kit for Ribonuclease T2 (RNASET2)

Rnase-T2; RNASE6PL; RNASE6-PL; Ribonuclease 6

  • CLIA Kit for Ribonuclease T2 (RNASET2) Packages (Simulation)
  • CLIA Kit for Ribonuclease T2 (RNASET2) Packages (Simulation)
  • CLIA Kit for Ribonuclease T2 (RNASET2) Results demonstration
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Ribonuclease T2 (RNASET2)

This assay has high sensitivity and excellent specificity for detection of Ribonuclease T2 (RNASET2).
No significant cross-reactivity or interference between Ribonuclease T2 (RNASET2) and analogues was observed.

Precision of the CLIA Kit for Ribonuclease T2 (RNASET2)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ribonuclease T2 (RNASET2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ribonuclease T2 (RNASET2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability of the CLIA Kit for Ribonuclease T2 (RNASET2)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Ribonuclease T2 (RNASET2)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Ribonuclease T2 (RNASET2)

The microplate provided in this kit has been pre-coated with an antibody specific to Ribonuclease T2 (RNASET2). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Ribonuclease T2 (RNASET2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Ribonuclease T2 (RNASET2) level in the sample or standard.;

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPA113Mu01 Recombinant Ribonuclease T2 (RNASET2) Positive Control; Immunogen; SDS-PAGE; WB.
RPA113Mu02 Recombinant Ribonuclease T2 (RNASET2) Positive Control; Immunogen; SDS-PAGE; WB.
PAA113Mu01 Polyclonal Antibody to Ribonuclease T2 (RNASET2) WB; IHC; ICC; IP.
PAA113Mu02 Polyclonal Antibody to Ribonuclease T2 (RNASET2) WB; IHC; ICC; IP.
SEA113Mu ELISA Kit for Ribonuclease T2 (RNASET2) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA113Mu CLIA Kit for Ribonuclease T2 (RNASET2) Chemiluminescent immunoassay for Antigen Detection.
LMA113Mu Multiplex Assay Kit for Ribonuclease T2 (RNASET2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK