CLIA Kit for Oxidized Low Density Lipoprotein (OxLDL)

OL

  • CLIA Kit for Oxidized Low Density Lipoprotein (OxLDL) Packages (Simulation)
  • CLIA Kit for Oxidized Low Density Lipoprotein (OxLDL) Packages (Simulation)
  • CLIA Kit for Oxidized Low Density Lipoprotein (OxLDL) Results demonstration
  • CCA527Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Oxidized Low Density Lipoprotein (OxLDL)

This assay has high sensitivity and excellent specificity for detection of Oxidized Low Density Lipoprotein (OxLDL).
No significant cross-reactivity or interference between Oxidized Low Density Lipoprotein (OxLDL) and analogues was observed.

Recovery of the CLIA Kit for Oxidized Low Density Lipoprotein (OxLDL)

Matrices listed below were spiked with certain level of recombinant Oxidized Low Density Lipoprotein (OxLDL) and the recovery rates were calculated by comparing the measured value to the expected amount of Oxidized Low Density Lipoprotein (OxLDL) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-97 94
EDTA plasma(n=5) 82-96 86
heparin plasma(n=5) 92-105 97

Precision of the CLIA Kit for Oxidized Low Density Lipoprotein (OxLDL)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Oxidized Low Density Lipoprotein (OxLDL) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Oxidized Low Density Lipoprotein (OxLDL) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Oxidized Low Density Lipoprotein (OxLDL)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Oxidized Low Density Lipoprotein (OxLDL) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-101% 80-101% 93-101% 93-105%
EDTA plasma(n=5) 87-95% 95-105% 83-97% 89-103%
heparin plasma(n=5) 98-105% 84-101% 98-105% 88-101%

Stability of the CLIA Kit for Oxidized Low Density Lipoprotein (OxLDL)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Oxidized Low Density Lipoprotein (OxLDL)

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.

Test principle of the CLIA Kit for Oxidized Low Density Lipoprotein (OxLDL)

The microplate provided in this kit has been pre-coated with an antibody specific to OxLDL. A competitive inhibition reaction is launched between biotin labeled OxLDL and unlabeled OxLDL (Standards or samples) with the pre-coated antibody specific to OxLDL. After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of OxLDL in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the OxLDL level in the sample or standard.

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
WEA527Mu Wide-range ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL) Enzyme-linked immunosorbent assay for Antigen Detection.
SEA527Mu ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL) Enzyme-linked immunosorbent assay for Antigen Detection.
CEA527Mu ELISA Kit for Oxidized Low Density Lipoprotein (OxLDL) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA527Mu CLIA Kit for Oxidized Low Density Lipoprotein (OxLDL) Chemiluminescent immunoassay for Antigen Detection.
CCA527Mu CLIA Kit for Oxidized Low Density Lipoprotein (OxLDL) Chemiluminescent immunoassay for Antigen Detection.
LMA527Mu Multiplex Assay Kit for Oxidized Low Density Lipoprotein (OxLDL) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA527Mu11 ELISA Kit DIY Materials for Oxidized Low Density Lipoprotein (OxLDL) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK