CLIA Kit for Interleukin 22 (IL22)

ILTIF; Zcyto18; IL-TIF; IL-D110; TIFa; TIFIL-23; IL-22; Cytokine Zcyto18; IL-10-Related T-Cell-Derived Inducible Factor

  • CLIA Kit for Interleukin 22 (IL22) Packages (Simulation)
  • CLIA Kit for Interleukin 22 (IL22) Packages (Simulation)
  • CLIA Kit for Interleukin 22 (IL22) Results demonstration
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Interleukin 22 (IL22)

This assay has high sensitivity and excellent specificity for detection of Interleukin 22 (IL22).
No significant cross-reactivity or interference between Interleukin 22 (IL22) and analogues was observed.

Recovery of the CLIA Kit for Interleukin 22 (IL22)

Matrices listed below were spiked with certain level of recombinant Interleukin 22 (IL22) and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 22 (IL22) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 101
EDTA plasma(n=5) 88-96 91
heparin plasma(n=5) 92-101 96

Precision of the CLIA Kit for Interleukin 22 (IL22)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 22 (IL22) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 22 (IL22) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Interleukin 22 (IL22)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 22 (IL22) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-101% 91-105% 79-101% 79-96%
EDTA plasma(n=5) 97-105% 80-90% 86-96% 98-105%
heparin plasma(n=5) 92-104% 91-99% 78-101% 80-101%

Stability of the CLIA Kit for Interleukin 22 (IL22)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Interleukin 22 (IL22)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Interleukin 22 (IL22)

The microplate provided in this kit has been pre-coated with an antibody specific to Interleukin 22 (IL22). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interleukin 22 (IL22). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interleukin 22 (IL22) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPC032Hu01 Recombinant Interleukin 22 (IL22) Positive Control; Immunogen; SDS-PAGE; WB.
EPC032Hu61 Eukaryotic Interleukin 22 (IL22) Positive Control; Immunogen; SDS-PAGE; WB.
APC032Hu01 Active Interleukin 22 (IL22) Cell culture; Activity Assays.
APC032Hu61 Active Interleukin 22 (IL22) Cell culture; Activity Assays.
PAC032Hu01 Polyclonal Antibody to Interleukin 22 (IL22) WB; IHC; ICC; IP.
FAC032Hu01 Anti-Interleukin 22 (IL22) Polyclonal Antibody Flow cytometry.
RAC032Hu21 Recombinant Antibody to Interleukin 22 (IL22) WB; IF; ICC; IHC; IP; FCM.
MAC032Hu21 Monoclonal Antibody to Interleukin 22 (IL22) WB; IHC; ICC; IP.
MAC032Hu23 Monoclonal Antibody to Interleukin 22 (IL22) WB; IHC; ICC; IP.
MAC032Hu22 Monoclonal Antibody to Interleukin 22 (IL22) WB
FAC032Hu52 APC-Linked Anti-Interleukin 22 (IL22) Monoclonal Antibody FCM
SEC032Hu ELISA Kit for Interleukin 22 (IL22) Enzyme-linked immunosorbent assay for Antigen Detection.
SCC032Hu CLIA Kit for Interleukin 22 (IL22) Chemiluminescent immunoassay for Antigen Detection.
LMC032Hu Multiplex Assay Kit for Interleukin 22 (IL22) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.