CLIA Kit for Granulin (GRN)

GEP; GP88; PCDGF; PEPI; PGRN; Proepithelin; Acrogranin; Glycoprotein of 88 Kda; Paragranulin

  • CLIA Kit for Granulin (GRN) Packages (Simulation)
  • CLIA Kit for Granulin (GRN) Packages (Simulation)
  • CLIA Kit for Granulin (GRN) Results demonstration
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Granulin (GRN)

This assay has high sensitivity and excellent specificity for detection of Granulin (GRN).
No significant cross-reactivity or interference between Granulin (GRN) and analogues was observed.

Recovery of the CLIA Kit for Granulin (GRN)

Matrices listed below were spiked with certain level of recombinant Granulin (GRN) and the recovery rates were calculated by comparing the measured value to the expected amount of Granulin (GRN) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-102 98
EDTA plasma(n=5) 91-99 94
heparin plasma(n=5) 93-105 102

Precision of the CLIA Kit for Granulin (GRN)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Granulin (GRN) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Granulin (GRN) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Granulin (GRN)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Granulin (GRN) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 99-105% 91-98% 80-105% 82-99%
EDTA plasma(n=5) 79-93% 80-97% 91-98% 87-105%
heparin plasma(n=5) 85-104% 96-103% 82-102% 90-104%

Stability of the CLIA Kit for Granulin (GRN)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Granulin (GRN)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Granulin (GRN)

The microplate provided in this kit has been pre-coated with an antibody specific to Granulin (GRN). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Granulin (GRN). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Granulin (GRN) level in the sample or standard.;

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
RPC513Ra01 Recombinant Granulin (GRN) Positive Control; Immunogen; SDS-PAGE; WB.
PAC513Ra01 Polyclonal Antibody to Granulin (GRN) WB; IHC; ICC; IP.
MAC513Ra21 Monoclonal Antibody to Granulin (GRN) WB; IHC; ICC; IP.
SEC513Ra ELISA Kit for Granulin (GRN) Enzyme-linked immunosorbent assay for Antigen Detection.
SCC513Ra CLIA Kit for Granulin (GRN) Chemiluminescent immunoassay for Antigen Detection.
LMC513Ra Multiplex Assay Kit for Granulin (GRN) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK