CLIA Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1)

AIF1; IRT1; Daintain; Protein G1; Allograft Inflammatory Factor 1

  • CLIA Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1) Packages (Simulation)
  • CLIA Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1) Packages (Simulation)
  • CLIA Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1) Results demonstration
  • SCC288Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1)

This assay has high sensitivity and excellent specificity for detection of Ionized Calcium-binding Adapter Molecule 1 (IBA1).
No significant cross-reactivity or interference between Ionized Calcium-binding Adapter Molecule 1 (IBA1) and analogues was observed.

Precision of the CLIA Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ionized Calcium-binding Adapter Molecule 1 (IBA1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ionized Calcium-binding Adapter Molecule 1 (IBA1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability of the CLIA Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1)

The microplate provided in this kit has been pre-coated with an antibody specific to Ionized Calcium-binding Adapter Molecule 1 (IBA1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Ionized Calcium-binding Adapter Molecule 1 (IBA1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Ionized Calcium-binding Adapter Molecule 1 (IBA1) level in the sample or standard.;

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
EPC288Mu61 Eukaryotic Ionized Calcium-binding Adapter Molecule 1 (IBA1) Positive Control; Immunogen; SDS-PAGE; WB.
RPC288Mu01 Recombinant Ionized Calcium-binding Adapter Molecule 1 (IBA1) Positive Control; Immunogen; SDS-PAGE; WB.
RPC288Mu02 Recombinant Ionized Calcium-binding Adapter Molecule 1 (IBA1) Positive Control; Immunogen; SDS-PAGE; WB.
PAC288Mu02 Polyclonal Antibody to Ionized Calcium-binding Adapter Molecule 1 (IBA1) WB; IHC; ICC; IP.
PAC288Mu01 Polyclonal Antibody to Ionized Calcium-binding Adapter Molecule 1 (IBA1) WB; IHC; ICC; IP.
LAC288Mu71 Biotin-Linked Polyclonal Antibody to Ionized Calcium-binding Adapter Molecule 1 (IBA1) WB; IHC; ICC.
SEC288Mu ELISA Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1) Enzyme-linked immunosorbent assay for Antigen Detection.
SCC288Mu CLIA Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1) Chemiluminescent immunoassay for Antigen Detection.
LMC288Mu Multiplex Assay Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK