Multiplex Assay Kit for Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array)

PDGF-A; PDGF1; Platelet Derived Growth Factor Alpha Polypeptide

  • Multiplex Assay Kit for Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array)

This assay has high sensitivity and excellent specificity for detection of Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery of the Multiplex Assay Kit for Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array)

Matrices listed below were spiked with certain level of recombinant Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-89 83
EDTA plasma(n=5) 78-101 81
heparin plasma(n=5) 94-101 97

Precision of the Multiplex Assay Kit for Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-97% 91-105% 85-99% 93-105%
EDTA plasma(n=5) 91-99% 80-101% 97-105% 96-104%
heparin plasma(n=5) 98-105% 85-93% 85-99% 79-101%

Stability of the Multiplex Assay Kit for Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array)

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array)

Anti-Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array) in the sample and corresponding value of MFI (Median Fluorescence Intensity). Flow Cytometer was used to determine and calculate the sample concentration.

GIVEAWAYS

Related products

Catalog No. Organism species: Oryctolagus cuniculus (Rabbit) Applications (RESEARCH USE ONLY!)
URPA528Rb01 Recombinant Platelet Derived Growth Factor Subunit A (PDGFA) Positive Control; Immunogen; SDS-PAGE; WB.
UPAA528Rb51 Polyclonal Antibody to Platelet Derived Growth Factor Subunit A (PDGFA) WB; IHC; ICC; IP.
UMAA528Rb21 Monoclonal Antibody to Platelet Derived Growth Factor Subunit A (PDGFA) WB; IHC; ICC; IP.
USEA528Rb ELISA Kit for Platelet Derived Growth Factor Subunit A (PDGFA) Enzyme-linked immunosorbent assay for Antigen Detection.
UCMA528Rb Multiplex Assay Kit for Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
ULMA528Rb Multiplex Assay Kit for Platelet Derived Growth Factor Subunit A (PDGFA) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK