Multiplex Assay Kit for Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array)
CCL7; FIC; MARC; NC28; MCP3; SCYA7; Chemokine C-C-Motif Ligand 7; Small Inducible Cytokine A7; Monocyte Chemoattractant Protein 3
- Product No.UCMA089Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Test MethodDouble-antibody Sandwich
- Assay Length4h
- Detection Range0.9766-1000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.3255pg/mL.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Download Instruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
-
FOB
US$ 143
For more details, please contact local distributors! US$ 149
For more details, please contact local distributors! US$ 157
For more details, please contact local distributors! US$ 168
For more details, please contact local distributors! US$ 179
For more details, please contact local distributors! US$ 195
For more details, please contact local distributors! US$ 220
For more details, please contact local distributors!US$ 275
For more details, please contact local distributors!
Specificity of the Multiplex Assay Kit for Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array)
This assay has high sensitivity and excellent specificity for detection of Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.
Recovery of the Multiplex Assay Kit for Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array)
Matrices listed below were spiked with certain level of recombinant Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 78-92 | 83 |
| EDTA plasma(n=5) | 98-105 | 101 |
| heparin plasma(n=5) | 96-105 | 99 |
Precision of the Multiplex Assay Kit for Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the Multiplex Assay Kit for Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 85-98% | 98-105% | 78-92% | 88-97% |
| EDTA plasma(n=5) | 94-102% | 94-102% | 79-93% | 85-99% |
| heparin plasma(n=5) | 79-101% | 84-97% | 95-104% | 95-102% |
Stability of the Multiplex Assay Kit for Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the Multiplex Assay Kit for Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array)
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
Test principle of the Multiplex Assay Kit for Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array)
Anti-Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Monocyte Chemotactic Protein 3 (MCP3) ,etc. by CBA (Cytometric Bead Array) in the sample and corresponding value of MFI (Median Fluorescence Intensity). Flow Cytometer was used to determine and calculate the sample concentration.