Multiplex Assay Kit for Estrone (E1) ,etc. by CBA (Cytometric Bead Array)

Oestrone

  • Multiplex Assay Kit for Estrone (E1) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for Estrone (E1) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Estrone (E1) ,etc. by CBA (Cytometric Bead Array)

This assay has high sensitivity and excellent specificity for detection of Estrone (E1) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Estrone (E1) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery of the Multiplex Assay Kit for Estrone (E1) ,etc. by CBA (Cytometric Bead Array)

Matrices listed below were spiked with certain level of Estrone (E1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Estrone (E1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-99 87
EDTA plasma(n=5) 94-102 98
heparin plasma(n=5) 83-103 89

Precision of the Multiplex Assay Kit for Estrone (E1) ,etc. by CBA (Cytometric Bead Array)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Estrone (E1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Estrone (E1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Estrone (E1) ,etc. by CBA (Cytometric Bead Array)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Estrone (E1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-88% 96-105% 84-101% 85-95%
EDTA plasma(n=5) 93-104% 78-98% 78-104% 96-104%
heparin plasma(n=5) 79-94% 78-103% 84-92% 79-95%

Stability of the Multiplex Assay Kit for Estrone (E1) ,etc. by CBA (Cytometric Bead Array)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Estrone (E1) ,etc. by CBA (Cytometric Bead Array)

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Estrone (E1) ,etc. by CBA (Cytometric Bead Array)

Anti-Estrone (E1) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads. A competitive inhibition reaction is launched between biotin labeled Estrone (E1) ,etc. by CBA (Cytometric Bead Array) and unlabeled Estrone (E1) ,etc. by CBA (Cytometric Bead Array) (Standards or samples) with the pre-coated antibody specific to Estrone (E1) ,etc. by CBA (Cytometric Bead Array). PE-labeled avidin was added. The amount of bound PE conjugate is reverse proportional to the concentration of Estrone (E1) ,etc. by CBA (Cytometric Bead Array) in the sample, the intensity of MFI developed is reverse proportional to the concentration of Estrone (E1) ,etc. by CBA (Cytometric Bead Array) in the sample.

GIVEAWAYS

INCREMENT SERVICES

Related products

Catalog No. Organism species: Pan-species (General) Applications (RESEARCH USE ONLY!)
UCPB003Ge11 BSA Conjugated Estrone (E1) Immunogen; SDS-PAGE; WB.
UCPB003Ge21 OVA Conjugated Estrone (E1) Immunogen; SDS-PAGE; WB.
UPAB003Ge01 Polyclonal Antibody to Estrone (E1) ELISA
UPAB003Ge02 Polyclonal Antibody to Estrone (E1) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
UMAB003Ge21 Monoclonal Antibody to Estrone (E1) ELISA
UMEB003Ge Mini Samples ELISA Kit for Estrone (E1) Enzyme-linked immunosorbent assay for Antigen Detection.
UCEB003Ge ELISA Kit for Estrone (E1) Enzyme-linked immunosorbent assay for Antigen Detection.
UIEB003Ge Instant ELISA Kit for Estrone (E1) Enzyme-linked immunosorbent assay for Antigen Detection.
UCCB003Ge CLIA Kit for Estrone (E1) Chemiluminescent immunoassay for Antigen Detection.
ULMB003Ge Multiplex Assay Kit for Estrone (E1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
UCMB003Ge Multiplex Assay Kit for Estrone (E1) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
UPSB003Ge11 Antibody Pair for Estrone (E1) ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays.
UKSB003Ge11 ELISA Kit DIY Materials for Estrone (E1) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK