Multiplex Assay Kit for Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array)

  • Multiplex Assay Kit for Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array)

This assay has high sensitivity and excellent specificity for detection of Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery of the Multiplex Assay Kit for Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array)

Matrices listed below were spiked with certain level of Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-96 88
EDTA plasma(n=5) 78-93 81
heparin plasma(n=5) 90-101 96

Precision of the Multiplex Assay Kit for Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-98% 81-103% 93-102% 86-96%
EDTA plasma(n=5) 78-102% 89-96% 95-102% 98-105%
heparin plasma(n=5) 81-94% 93-101% 81-104% 81-104%

Stability of the Multiplex Assay Kit for Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array)

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array)

Anti-Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads. A competitive inhibition reaction is launched between biotin labeled Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array) and unlabeled Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array) (Standards or samples) with the pre-coated antibody specific to Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array). PE-labeled avidin was added. The amount of bound PE conjugate is reverse proportional to the concentration of Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array) in the sample, the intensity of MFI developed is reverse proportional to the concentration of Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array) in the sample.

GIVEAWAYS

INCREMENT SERVICES

Related products

Catalog No. Organism species: Pan-species (General) Applications (RESEARCH USE ONLY!)
UMAA911Ge21 Monoclonal Antibody to Aldosterone (ALD) ELISA
UMAA911Ge22 Monoclonal Antibody to Aldosterone (ALD) ELISA
UMEA911Ge Mini Samples ELISA Kit for Aldosterone (ALD) Enzyme-linked immunosorbent assay for Antigen Detection.
UCEA911Ge ELISA Kit for Aldosterone (ALD) Enzyme-linked immunosorbent assay for Antigen Detection.
UCCA911Ge CLIA Kit for Aldosterone (ALD) Chemiluminescent immunoassay for Antigen Detection.
UCMA911Ge Multiplex Assay Kit for Aldosterone (ALD) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
ULMA911Ge Multiplex Assay Kit for Aldosterone (ALD) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK