Multiplex Assay Kit for Albumin (ALB) ,etc. by CBA (Cytometric Bead Array)

Serum albumin

  • Multiplex Assay Kit for Albumin (ALB) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for Albumin (ALB) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Albumin (ALB) ,etc. by CBA (Cytometric Bead Array)

This assay has high sensitivity and excellent specificity for detection of Albumin (ALB) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Albumin (ALB) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery of the Multiplex Assay Kit for Albumin (ALB) ,etc. by CBA (Cytometric Bead Array)

Matrices listed below were spiked with certain level of recombinant Albumin (ALB) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Albumin (ALB) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 93-102 97
EDTA plasma(n=5) 88-95 91
heparin plasma(n=5) 93-103 99

Precision of the Multiplex Assay Kit for Albumin (ALB) ,etc. by CBA (Cytometric Bead Array)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Albumin (ALB) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Albumin (ALB) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Albumin (ALB) ,etc. by CBA (Cytometric Bead Array)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Albumin (ALB) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 84-104% 85-104% 84-94% 98-105%
EDTA plasma(n=5) 87-97% 81-97% 85-101% 88-101%
heparin plasma(n=5) 79-98% 97-104% 94-101% 78-92%

Stability of the Multiplex Assay Kit for Albumin (ALB) ,etc. by CBA (Cytometric Bead Array)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Albumin (ALB) ,etc. by CBA (Cytometric Bead Array)

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Albumin (ALB) ,etc. by CBA (Cytometric Bead Array)

Anti-Albumin (ALB) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads. A competitive inhibition reaction is launched between biotin labeled Albumin (ALB) ,etc. by CBA (Cytometric Bead Array) and unlabeled Albumin (ALB) ,etc. by CBA (Cytometric Bead Array) (Standards or samples) with the pre-coated antibody specific to Albumin (ALB) ,etc. by CBA (Cytometric Bead Array). PE-labeled avidin was added. The amount of bound PE conjugate is reverse proportional to the concentration of Albumin (ALB) ,etc. by CBA (Cytometric Bead Array) in the sample, the intensity of MFI developed is reverse proportional to the concentration of Albumin (ALB) ,etc. by CBA (Cytometric Bead Array) in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
UNPB028Ra01 Native Albumin (ALB) Positive Control; Immunogen; SDS-PAGE; WB.
URPB028Ra01 Recombinant Albumin (ALB) Positive Control; Immunogen; SDS-PAGE; WB.
UEPB028Ra61 Eukaryotic Albumin (ALB) Positive Control; Immunogen; SDS-PAGE; WB.
UPAB028Ra01 Polyclonal Antibody to Albumin (ALB) WB; IHC
ULAB028Ra81 FITC-Linked Polyclonal Antibody to Albumin (ALB) WB; IHC; ICC; IF.
ULAB028Ra71 Biotin-Linked Polyclonal Antibody to Albumin (ALB) WB
UMAB028Ra23 Monoclonal Antibody to Albumin (ALB) IHC
UMAB028Ra24 Monoclonal Antibody to Albumin (ALB) IHC
UMAB028Ra22 Monoclonal Antibody to Albumin (ALB) WB
UMAB028Ra27 Monoclonal Antibody to Albumin (ALB) WB
UMAB028Ra28 Monoclonal Antibody to Albumin (ALB) WB
UMAB028Ra21 Monoclonal Antibody to Albumin (ALB) ICC/IF
UOEB028Ra OneStep ELISA Kit for Albumin (ALB) Enzyme-linked immunosorbent assay for Antigen Detection.
UCEB028Ra ELISA Kit for Albumin (ALB) Enzyme-linked immunosorbent assay for Antigen Detection.
UCCB028Ra CLIA Kit for Albumin (ALB) Chemiluminescent immunoassay for Antigen Detection.
UCMB028Ra Multiplex Assay Kit for Albumin (ALB) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
ULMB028Ra Multiplex Assay Kit for Albumin (ALB) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
UKSB028Ra11 ELISA Kit DIY Materials for Albumin (ALB) Main materials for "Do It (ELISA Kit) Yourself".