Multiplex Assay Kit for Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array)

CD166; MEMD; Activated Leucocyte Cell Adhesion Molecule

  • Multiplex Assay Kit for Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array)

This assay has high sensitivity and excellent specificity for detection of Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery of the Multiplex Assay Kit for Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array)

Matrices listed below were spiked with certain level of recombinant Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-94 87
EDTA plasma(n=5) 89-101 94
heparin plasma(n=5) 91-99 95

Precision of the Multiplex Assay Kit for Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 92-103% 78-101% 87-101%
EDTA plasma(n=5) 84-98% 82-96% 89-97% 79-88%
heparin plasma(n=5) 78-98% 80-94% 96-105% 95-102%

Stability of the Multiplex Assay Kit for Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array)

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array)

TCMB

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
URPA002Hu01 Recombinant Activated Leukocyte Cell Adhesion Molecule (ALCAM) Positive Control; Immunogen; SDS-PAGE; WB.
UPAA002Hu01 Polyclonal Antibody to Activated Leukocyte Cell Adhesion Molecule (ALCAM) WB
UFAA002Hu01 Anti-Activated Leukocyte Cell Adhesion Molecule (ALCAM) Polyclonal Antibody Flow cytometry.
ULAA002Hu71 Biotin-Linked Polyclonal Antibody to Activated Leukocyte Cell Adhesion Molecule (ALCAM) WB; IHC; ICC.
ULAA002Hu81 FITC-Linked Polyclonal Antibody to Activated Leukocyte Cell Adhesion Molecule (ALCAM) WB; IHC; ICC; IF.
UMAA002Hu22 Monoclonal Antibody to Activated Leukocyte Cell Adhesion Molecule (ALCAM) IHC
UMAA002Hu23 Monoclonal Antibody to Activated Leukocyte Cell Adhesion Molecule (ALCAM) ICC/IF
UMAA002Hu24 Monoclonal Antibody to Activated Leukocyte Cell Adhesion Molecule (ALCAM) ICC/IF
UMAA002Hu21 Monoclonal Antibody to Activated Leukocyte Cell Adhesion Molecule (ALCAM) IHC
URAA002Hu21 Recombinant Antibody to Activated Leukocyte Cell Adhesion Molecule (ALCAM) FCM
USEA002Hu ELISA Kit for Activated Leukocyte Cell Adhesion Molecule (ALCAM) Enzyme-linked immunosorbent assay for Antigen Detection.
USCA002Hu CLIA Kit for Activated Leukocyte Cell Adhesion Molecule (ALCAM) Chemiluminescent immunoassay for Antigen Detection.
ULMA002Hu Multiplex Assay Kit for Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
UCMA002Hu Multiplex Assay Kit for Activated Leukocyte Cell Adhesion Molecule (ALCAM) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
GUESTBOOK